All MIBs › BLADE-MIB › spClockTimezoneSetting
spClockTimezoneSetting
Module: BLADE-MIB
OID (symbolic): BLADE-MIB::spClockTimezoneSetting
OID (numeric): 1.3.6.1.4.1.2.3.51.2.4.4.2
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: ASM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings.
The following table lists GMT offsets and associated DST information. DST is not observed in time zones where the 'Observe DST' value does not contain 'yes' in the table. Also, note that in some cases additional information is required to determine the clock adjustment when DST is observed. The additional information is required when the GMT offset being written is +2:00 or +10:00.
Examples -to set the GMT offset to +3:30, set the value to:'+3:30,no'
-for Eastern Standard Time and observing DST, set the value to:'-5:00,yes'
-for Egypt and observing DST, set the value to:'+2:00,yes,6'
GMT Observe Additional Offset DST? DST value ______ _______ __________ +0:00 yes|no +1:00 yes|no +2:00 yes|no When 'Observe DST?' value is 'yes': 5 (for E.Europe) 4 (for GTB) 6 (for Egypt) 7 (for FLE) +3:00 yes|no +3:30 yes|no +4:00 no +4:30 no +5:00 yes|no +5:30 no +6:00 no +7:00 no +8:00 no +9:00 yes|no +9:30 yes|no +10:00 yes|no When 'Observe DST?' value is 'yes': 9 (for AUS Eastern) 10 (for Tasmania) 4 (for Vladivostok) +11:00 no +12:00 yes|no -12:00 no -11:00 no -10:00 no -9:00 yes|no -8:00 yes|no -7:00 yes|no -6:00 yes|no -5:00 yes|no -4:00 yes|no -3:30 yes|no -3:00 yes|no -2:00 yes|no -1:00 yes|no
What is spClockTimezoneSetting?
Sets the management module's GMT time-zone offset and whether Daylight Saving Time (DST) is observed, written as a string such as '-5:00,yes' for U.S. Eastern time with DST, or '+3:30,no' for a zone with no DST. Certain offsets (+2:00 and +10:00) additionally require a numeric DST-region code because more than one DST rule applies at that offset.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.4.4.2 snmpwalk -v2c -c public <target> BLADE-MIB::spClockTimezoneSetting
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.4.4.2.1 snmpget -v2c -c public <target> BLADE-MIB::spClockTimezoneSetting.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2.3.51.2.4.4.2.1 s <value>
Start monitoring IBM BladeCenter Management Module (MM) (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLADE-MIB::spClockTimezoneSetting OID value, configure state conditions and alerts, and monitor any IBM BladeCenter Management Module (MM) (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2 | ibm | BLADE-MIB |
| 1.3.6.1.4.1.2.3 | ibmAgents | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51 | netfinitySupportProcessorAgent | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2 | bladeCenterSnmpMIB | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.4 | configureSP | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.4.4 | spClock | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.4.4.2 | spClockTimezoneSetting | BLADE-MIB |