All MIBs › BLADE-MIB › smRestartAndRunFullDiag
smRestartAndRunFullDiag
Module: BLADE-MIB
OID (symbolic): BLADE-MIB::smRestartAndRunFullDiag
OID (numeric): 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This option is not supported on all I/O modules.
NOTE: Value returned for the GET command is meaningless for this MIB.
What is smRestartAndRunFullDiag?
Setting this read-write field to execute(1) power-cycles the selected switch module bay and runs its full diagnostic test package, as opposed to the standard or extended diagnostic siblings. Because the full package can take over 5 minutes and isn't supported on every I/O module, admins should reserve it for deep troubleshooting rather than routine restarts. A GET on this object returns no meaningful value; only the SET action matters.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12 snmpwalk -v2c -c public <target> BLADE-MIB::smRestartAndRunFullDiag
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12.1 snmpget -v2c -c public <target> BLADE-MIB::smRestartAndRunFullDiag.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12.1 i <value>
Start monitoring IBM BladeCenter Management Module (MM) (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLADE-MIB::smRestartAndRunFullDiag OID value, configure state conditions and alerts, and monitor any IBM BladeCenter Management Module (MM) (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2 | ibm | BLADE-MIB |
| 1.3.6.1.4.1.2.3 | ibmAgents | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51 | netfinitySupportProcessorAgent | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2 | bladeCenterSnmpMIB | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.22 | bladeCenter | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.22.3 | switchModule | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.22.3.1 | switchModuleControl | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.22.3.1.7 | smPowerRestartTable | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1 | smPowerRestartEntry | BLADE-MIB |
| 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12 | smRestartAndRunFullDiag | BLADE-MIB |