BLADE-MIB :: bladePlus1pt25VoltHighWarning

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBLADE-MIBbladePlus1pt25VoltHighWarning

bladePlus1pt25VoltHighWarning

Module: BLADE-MIB

OID (symbolic): BLADE-MIB::bladePlus1pt25VoltHighWarning

OID (numeric): 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.

What is bladePlus1pt25VoltHighWarning?

The upper voltage warning threshold for the blade's +1.25V rail; a warning alert fires if the measured +1.25V voltage rises above this value. The string instead reads 'Not Readable!' if the sensor isn't supported, or 'No Voltage' if the rail doesn't exist or the blade is off.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18
snmpwalk -v2c -c public <target> BLADE-MIB::bladePlus1pt25VoltHighWarning

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18.1
snmpget -v2c -c public <target> BLADE-MIB::bladePlus1pt25VoltHighWarning.1

Start monitoring IBM BladeCenter Management Module (MM) (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLADE-MIB::bladePlus1pt25VoltHighWarning OID value, configure state conditions and alerts, and monitor any IBM BladeCenter Management Module (MM) (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2ibmBLADE-MIB
1.3.6.1.4.1.2.3ibmAgentsBLADE-MIB
1.3.6.1.4.1.2.3.51netfinitySupportProcessorAgentBLADE-MIB
1.3.6.1.4.1.2.3.51.2bladeCenterSnmpMIBBLADE-MIB
1.3.6.1.4.1.2.3.51.2.22bladeCenterBLADE-MIB
1.3.6.1.4.1.2.3.51.2.22.1processorBladeBLADE-MIB
1.3.6.1.4.1.2.3.51.2.22.1.5bladeMonitorsBLADE-MIB
1.3.6.1.4.1.2.3.51.2.22.1.5.6bladeVoltageThresholdsTableBLADE-MIB
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1bladeVoltageThresholdsEntryBLADE-MIB
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18bladePlus1pt25VoltHighWarningBLADE-MIB