All MIBs › BIANCA-X8000-MIBSYS-MIB › sysX8ConfigPowerSupply1Temp
sysX8ConfigPowerSupply1Temp
Module: BIANCA-X8000-MIBSYS-MIB
OID (symbolic): BIANCA-X8000-MIBSYS-MIB::sysX8ConfigPowerSupply1Temp
OID (numeric): 1.3.6.1.4.1.272.4.17.3.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This variable shows the actual power supply temperature in the unit Celsius.
What is sysX8ConfigPowerSupply1Temp?
Reports the current temperature of power supply 1, read-only, in Celsius.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.272.4.17.3.1.2 snmpwalk -v2c -c public <target> BIANCA-X8000-MIBSYS-MIB::sysX8ConfigPowerSupply1Temp
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.272.4.17.3.1.2.1 snmpget -v2c -c public <target> BIANCA-X8000-MIBSYS-MIB::sysX8ConfigPowerSupply1Temp.1
Start monitoring bintec elmeg BIANCA X8000-series broadband router (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BIANCA-X8000-MIBSYS-MIB::sysX8ConfigPowerSupply1Temp OID value, configure state conditions and alerts, and monitor any bintec elmeg BIANCA X8000-series broadband router (legacy) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.272 | bintec | BIANCA-BOX-ISDN-MIB |
| 1.3.6.1.4.1.272.4 | bibo | BIANCA-BOX-ISDN-MIB |
| 1.3.6.1.4.1.272.4.17 | sys | BIANCA-BRICK-MIBSYS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.272.4.17.3 | x8 | BIANCA-X8000-MIBSYS-MIB |
| 1.3.6.1.4.1.272.4.17.3.1 | sysX8Config | BIANCA-X8000-MIBSYS-MIB |
| 1.3.6.1.4.1.272.4.17.3.1.2 | sysX8ConfigPowerSupply1Temp | BIANCA-X8000-MIBSYS-MIB |