BIANCA-BRICK-MIBRES-MIB :: cpuTotalUser

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › BIANCA-BRICK-MIBRES-MIB › cpuTotalUser

cpuTotalUser

Module: BIANCA-BRICK-MIBRES-MIB

OID (symbolic): BIANCA-BRICK-MIBRES-MIB::cpuTotalUser

OID (numeric): 1.3.6.1.4.1.272.4.17.4.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Total time in seconds spent in user mode since booting.

What is cpuTotalUser?

The cumulative seconds the CPU has spent executing user-mode code since the device booted. This long-term metric shows total computational load over the device's lifetime. Example: after a week of operation, this might show 300,000 seconds of user CPU time.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.272.4.17.4.1.1.3
snmpwalk -v2c -c public <target> BIANCA-BRICK-MIBRES-MIB::cpuTotalUser

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.272.4.17.4.1.1.3.1
snmpget -v2c -c public <target> BIANCA-BRICK-MIBRES-MIB::cpuTotalUser.1

Start monitoring bintec BIANCA/BRICK ISDN/VPN routers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BIANCA-BRICK-MIBRES-MIB::cpuTotalUser OID value, configure state conditions and alerts, and monitor any bintec BIANCA/BRICK ISDN/VPN routers (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a bintec BIANCA/BRICK ISDN/VPN router (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cpuTotalUser into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the total time in seconds spent in user mode since booting. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 85%, a common warning threshold before sustained high load affects performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.272bintecBIANCA-BOX-ISDN-MIB
1.3.6.1.4.1.272.4biboBIANCA-BOX-ISDN-MIB
1.3.6.1.4.1.272.4.17sysBIANCA-BRICK-MIBSYS-MIB
1.3.6.1.4.1.272.4.17.4resourceBINTEC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.272.4.17.4.1cpuTableBIANCA-BRICK-MIBRES-MIB
1.3.6.1.4.1.272.4.17.4.1.1cpuEntryBIANCA-BRICK-MIBRES-MIB
1.3.6.1.4.1.272.4.17.4.1.1.3cpuTotalUserBIANCA-BRICK-MIBRES-MIB