BASEBRDD-MIB-MIB :: pwrSupplyOnlineAtt5

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBASEBRDD-MIB-MIBpwrSupplyOnlineAtt5

pwrSupplyOnlineAtt5

Module: BASEBRDD-MIB-MIB

OID (symbolic): BASEBRDD-MIB-MIB::pwrSupplyOnlineAtt5

OID (numeric): 1.3.6.1.4.1.674.10891.304.1.5

Node type: OBJECT-TYPE

Type: DmiDisplaystring

Access: read-write

Description: The current online status of this power supply. Setting this value to FALSE will turn off the power supply, setting it to TRUE will turn on the power supply.

What is pwrSupplyOnlineAtt5?

Read-write value indicating and controlling whether a power supply is currently online and actively supplying power.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10891.304.1.5
snmpwalk -v2c -c public <target> BASEBRDD-MIB-MIB::pwrSupplyOnlineAtt5

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10891.304.1.5.1
snmpget -v2c -c public <target> BASEBRDD-MIB-MIB::pwrSupplyOnlineAtt5.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.674.10891.304.1.5.1 s <value>

Start monitoring Dell server/network appliance hardware (baseboard management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BASEBRDD-MIB-MIB::pwrSupplyOnlineAtt5 OID value, configure state conditions and alerts, and monitor any Dell server/network appliance hardware (baseboard management) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10891server2BASEBRDD-MIB
1.3.6.1.4.1.674.10891.304dellRedundantPowerSupplyTableBASEBRDD-MIB
1.3.6.1.4.1.674.10891.304.1dellRedundantPowerSupplyEntryBASEBRDD-MIB
Numeric OIDNameModule