AVICI-BAY-MIB :: aviciBayVoltageNotification

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAVICI-BAY-MIBaviciBayVoltageNotification

aviciBayVoltageNotification

Module: AVICI-BAY-MIB

OID (symbolic): AVICI-BAY-MIB::aviciBayVoltageNotification

OID (numeric): 1.3.6.1.4.1.2474.1.4.2.0.1

Node type: NOTIFICATION-TYPE

Description: A Voltage notification is sent when a change is detected in the 5
volt backplane communication rails.  These backplane 
communication rails are used by the bay controller to
communicate with the occupant of a given slot.  There are 8
rails, each servicing the slots in one half of a shelf in the
bay (aviciBayVoltageIndex == rail):

 Rail   Slots
==============
  1    1 - 5
  2    6 - 10 
  3   11 - 15
  4   16 - 20
  5   21 - 25
  6   26 - 30
  7   31 - 35
  8   36 - 40

If the voltage is out of specification, the communication path
will not function.  When a given backplane communication channel
is not functioning, modules serviced by this rail cannot be
discovered (if a module is inserted) and will not be authorized
to boot (if an existing module reboots).  The current voltage is
reported in the aviciBayVoltage object.  A human readable
description of the event triggering this notification is
included in the aviciSysTrapDescr object.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' AVICI-BAY-MIB::aviciBayVoltageNotification
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.2474.1.4.2.0.1

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:55832->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (421331992) 48 days, 18:21:59.92
  SNMPv2-MIB::snmpTrapOID.0 = OID: AVICI-BAY-MIB::aviciBayVoltageNotification

Start monitoring Avici Systems core/backbone routers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AVICI-BAY-MIB::aviciBayVoltageNotification OID value, configure state conditions and alerts, and monitor any Avici Systems core/backbone routers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2474aviciAVICI-SMI
1.3.6.1.4.1.2474.1aviciMibsAVICI-SMI
Numeric OIDNameModule
1.3.6.1.4.1.2474.1.4aviciBayMIBAVICI-BAY-MIB
1.3.6.1.4.1.2474.1.4.2aviciBayNotificationsAVICI-BAY-MIB
1.3.6.1.4.1.2474.1.4.2.0aviciBayNotificationPrefixAVICI-BAY-MIB
1.3.6.1.4.1.2474.1.4.2.0.1aviciBayVoltageNotificationAVICI-BAY-MIB