AVIAT-RXPERFORMANCE-MIB :: aviatRxPerformBerReadingMean

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › AVIAT-RXPERFORMANCE-MIB › aviatRxPerformBerReadingMean

aviatRxPerformBerReadingMean

Module: AVIAT-RXPERFORMANCE-MIB

OID (symbolic): AVIAT-RXPERFORMANCE-MIB::aviatRxPerformBerReadingMean

OID (numeric): 1.3.6.1.4.1.2509.9.15.2.2.1.7

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: This is the mean reading of the Bit Error Ratio of the radio.

What is aviatRxPerformBerReadingMean?

This reports the mean Bit Error Ratio of the radio link, i.e. the average proportion of bits received in error, giving a baseline sense of link quality over the monitoring period.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2509.9.15.2.2.1.7
snmpwalk -v2c -c public <target> AVIAT-RXPERFORMANCE-MIB::aviatRxPerformBerReadingMean

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2509.9.15.2.2.1.7.1
snmpget -v2c -c public <target> AVIAT-RXPERFORMANCE-MIB::aviatRxPerformBerReadingMean.1

Start monitoring Aviat Networks microwave radio links (point-to-point backhaul) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AVIAT-RXPERFORMANCE-MIB::aviatRxPerformBerReadingMean OID value, configure state conditions and alerts, and monitor any Aviat Networks microwave radio links (point-to-point backhaul) from a single console.

How to Use in IPNetwork Monitor

Select an Aviat Networks microwave radio link (point-to-point backhaul) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type aviatRxPerformBerReadingMean into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This is the mean reading of the Bit Error Ratio of the radio. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2509dmcSTXN-GLOBALREGISTER-MIB
1.3.6.1.4.1.2509.9aviatModulesSTXN-GLOBALREGISTER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2509.9.15aviatRxPerformanceModuleAVIAT-RXPERFORMANCE-MIB
1.3.6.1.4.1.2509.9.15.2aviatRxPerformanceMIBObjsAVIAT-RXPERFORMANCE-MIB
1.3.6.1.4.1.2509.9.15.2.2aviatRxPerformTableAVIAT-RXPERFORMANCE-MIB
1.3.6.1.4.1.2509.9.15.2.2.1aviatRxPerformEntryAVIAT-RXPERFORMANCE-MIB
1.3.6.1.4.1.2509.9.15.2.2.1.7aviatRxPerformBerReadingMeanAVIAT-RXPERFORMANCE-MIB