ATMF-CES :: atmfCESPointerParityErrors

MIB Reference — IPNetwork Monitor

All MIBsATMF-CESatmfCESPointerParityErrors

atmfCESPointerParityErrors

Module: ATMF-CES

OID (symbolic): ATMF-CES::atmfCESPointerParityErrors

OID (numeric): 1.3.6.1.4.1.353.5.2.2.1.3.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description:

This records the count of the number of events in which the AAL1 reassembler detects a parity check failure at the point where a structured data pointer is expected. This count is only meaningful for structured CES modes, as unstructured CES modes do not use pointers. For unstructured CES modes, this count, if present, should indicate zero.

What is atmfCESPointerParityErrors?

Records how many times the AAL1 reassembler detected a parity check failure at a location where a structured data pointer was expected. Like pointer reframes, this counter applies only to structured CES modes and indicates data integrity issues in the ATM cell stream.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.353.5.2.2.1.3.1.4
snmpwalk -v2c -c public <target> ATMF-CES::atmfCESPointerParityErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.353.5.2.2.1.3.1.4.1
snmpget -v2c -c public <target> ATMF-CES::atmfCESPointerParityErrors.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.353atmForumATM-FORUM-SNMP-M4-MIB
1.3.6.1.4.1.353.5atmForumNetworkManagementATM-FORUM-SNMP-M4-MIB
1.3.6.1.4.1.353.5.2atmfCESmibATMF-CES
1.3.6.1.4.1.353.5.2.2atmfCESATMF-CES
1.3.6.1.4.1.353.5.2.2.1atmfCESObjectsATMF-CES
1.3.6.1.4.1.353.5.2.2.1.3atmfCESStatsTableATMF-CES
1.3.6.1.4.1.353.5.2.2.1.3.1atmfCESStatsEntryATMF-CES
1.3.6.1.4.1.353.5.2.2.1.3.1.4atmfCESPointerParityErrorsATMF-CES