ALCATEL-IND1-TIMETRA-CHASSIS-MIB :: tmnxHwTemperature

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsALCATEL-IND1-TIMETRA-CHASSIS-MIBtmnxHwTemperature

tmnxHwTemperature

Module: ALCATEL-IND1-TIMETRA-CHASSIS-MIB

OID (symbolic): ALCATEL-IND1-TIMETRA-CHASSIS-MIB::tmnxHwTemperature

OID (numeric): 1.3.6.1.4.1.6527.3.1.2.2.1.8.1.18

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned.

What is tmnxHwTemperature?

Reports the current temperature in degrees Celsius measured by the hardware component's built-in sensor. A value of -1 is returned for components that do not have a temperature sensor.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.2.1.8.1.18
snmpwalk -v2c -c public <target> ALCATEL-IND1-TIMETRA-CHASSIS-MIB::tmnxHwTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.2.1.8.1.18.1
snmpget -v2c -c public <target> ALCATEL-IND1-TIMETRA-CHASSIS-MIB::tmnxHwTemperature.1

Start monitoring Nokia (Alcatel-Lucent) 7750 SR-series service routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALCATEL-IND1-TIMETRA-CHASSIS-MIB::tmnxHwTemperature OID value, configure state conditions and alerts, and monitor any Nokia (Alcatel-Lucent) 7750 SR-series service routers from a single console.

How to Use in IPNetwork Monitor

Select a Nokia (Alcatel-Lucent) 7750 SR-series service router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type tmnxHwTemperature into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the current temperature reading from this hardware component's sensor, in degrees Celsius (-1 if the component has no sensor). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds 60°C, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2tmnxSRObjsALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.2.2tmnxHwObjsALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.1tmnxChassisObjsALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.1.8tmnxHwTableALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.1.8.1tmnxHwEntryALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.2.2.1.8.1.18tmnxHwTemperatureALCATEL-IND1-TIMETRA-CHASSIS-MIB