ALCATEL-IND1-TIMETRA-CHASSIS-MIB :: tmnxEqSyncIfTimingRef2AlarmClear

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsALCATEL-IND1-TIMETRA-CHASSIS-MIBtmnxEqSyncIfTimingRef2AlarmClear

tmnxEqSyncIfTimingRef2AlarmClear

Module: ALCATEL-IND1-TIMETRA-CHASSIS-MIB

OID (symbolic): ALCATEL-IND1-TIMETRA-CHASSIS-MIB::tmnxEqSyncIfTimingRef2AlarmClear

OID (numeric): 1.3.6.1.4.1.6527.3.1.3.2.1.0.31

Node type: NOTIFICATION-TYPE

Description: Generated when an alarm condition on the second timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

What is tmnxEqSyncIfTimingRef2AlarmClear?

This notification is generated when an alarm condition on the second timing reference input is cleared, indicating recovery of a timing synchronization issue. The notification includes indices from the CPM card table to identify which timing reference recovered. Network operators use this to confirm that backup timing sources are functioning properly again after a failure.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' ALCATEL-IND1-TIMETRA-CHASSIS-MIB::tmnxEqSyncIfTimingRef2AlarmClear
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.2.1.0.31

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:64487->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (164113895) 18 days, 23:52:18.95
  SNMPv2-MIB::snmpTrapOID.0 = OID: ALCATEL-IND1-TIMETRA-CHASSIS-MIB::tmnxEqSyncIfTimingRef2AlarmClear

Start monitoring Nokia (Alcatel-Lucent) 7750 SR-series service routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALCATEL-IND1-TIMETRA-CHASSIS-MIB::tmnxEqSyncIfTimingRef2AlarmClear OID value, configure state conditions and alerts, and monitor any Nokia (Alcatel-Lucent) 7750 SR-series service routers from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.3tmnxSRNotifyPrefixALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.3.2tmnxHwNotificationALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.3.2.1tmnxChassisNotifyPrefixALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.3.2.1.0tmnxChassisNotificationALCATEL-IND1-TIMETRA-CHASSIS-MIB
1.3.6.1.4.1.6527.3.1.3.2.1.0.31tmnxEqSyncIfTimingRef2AlarmClearALCATEL-IND1-TIMETRA-CHASSIS-MIB