ADSL2-LINE-MIB :: adsl2SCStatusLog

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADSL2-LINE-MIBadsl2SCStatusLog

adsl2SCStatusLog

Module: ADSL2-LINE-MIB

OID (symbolic): ADSL2-LINE-MIB::adsl2SCStatusLog

OID (numeric): 1.3.6.1.2.1.10.238.1.2.2.1.11

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: An array of up to 512 real H(f) logarithmic representation values in dB for the respective transmission direction. It is designed to support up to 512 (downstream) sub-carriers. The number of utilized values on downstream direction depends on NSCds, and on upstream direction it depends on NSCus. This value is referred to here as NSC. Each array entry represents the real Hlog(f = i*Df) value for a particular sub-carrier index i, (0 <= i < NSC). The real Hlog(f) value is represented as (6-m(i)/10), with m(i) in the range 0 to 1022. A special value m=1023 indicates that no measurement could be done for the subcarrier because it is out of the passband or that the attenuation is out of range to be represented. This parameter is applicable in loop diagnostic procedure and initialization. Each value in this array is 16 bits wide and is stored in big endian format.

What is adsl2SCStatusLog?

This array stores up to 512 per-subcarrier channel gain values in dB, showing how much signal loss occurs at each frequency during the diagnostic window. Network engineers examine this profile to identify which frequencies are heavily attenuated or noisy, which helps pinpoint the cause of poor line performance (distance, interference, or quality issues). Example: a profile like [-30dB, -28dB, -32dB, -40dB, ...] shows progressively higher frequencies lose more signal, indicating a long or poor-quality line.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.238.1.2.2.1.11
snmpwalk -v2c -c public <target> ADSL2-LINE-MIB::adsl2SCStatusLog

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.238.1.2.2.1.11.1
snmpget -v2c -c public <target> ADSL2-LINE-MIB::adsl2SCStatusLog.1

Start monitoring ADSL2/ADSL2+ DSLAMs and CPE modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADSL2-LINE-MIB::adsl2SCStatusLog OID value, configure state conditions and alerts, and monitor any ADSL2/ADSL2+ DSLAMs and CPE modems from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
Numeric OIDNameModule
1.3.6.1.2.1.10.238adsl2MIBADSL2-LINE-MIB
1.3.6.1.2.1.10.238.1adsl2ADSL2-LINE-MIB
1.3.6.1.2.1.10.238.1.2adsl2StatusADSL2-LINE-MIB
1.3.6.1.2.1.10.238.1.2.2adsl2SCStatusTableADSL2-LINE-MIB
1.3.6.1.2.1.10.238.1.2.2.1adsl2SCStatusEntryADSL2-LINE-MIB
1.3.6.1.2.1.10.238.1.2.2.1.11adsl2SCStatusLogADSL2-LINE-MIB