ADN-ENV-MIB :: adnFrtChanSiMinDlyAmt

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-ENV-MIBadnFrtChanSiMinDlyAmt

adnFrtChanSiMinDlyAmt

Module: ADN-ENV-MIB

OID (symbolic): ADN-ENV-MIB::adnFrtChanSiMinDlyAmt

OID (numeric): 1.3.6.1.4.1.637.3.1.8.5.1.1.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: If the minimum delay change calculated using adnFrtChanSiMinDlyPct is less than this field, the minimum delay change a periodic delay measurement can consider to be significant is set equal to this field instead of the calculated value.

What is adnFrtChanSiMinDlyAmt?

This OID sets an absolute minimum threshold (in integer units, typically milliseconds) for delay changes to be considered significant, overriding the percentage calculation if the calculated value is smaller. This provides a safety floor so even a very low percentage threshold won't report trivial delay changes. For example, if MinDlyAmt is set to 10, a delay increase from 5 to 8 (a 60% change) is still ignored because it is smaller than 10.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.1.1.1.14
snmpwalk -v2c -c public <target> ADN-ENV-MIB::adnFrtChanSiMinDlyAmt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.1.1.1.14.1
snmpget -v2c -c public <target> ADN-ENV-MIB::adnFrtChanSiMinDlyAmt.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.637.3.1.8.5.1.1.1.14.1 i <value>

Start monitoring Frame Relay access equipment (FRANP signalling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-ENV-MIB::adnFrtChanSiMinDlyAmt OID value, configure state conditions and alerts, and monitor any Frame Relay access equipment (FRANP signalling) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.8adnEnvironmentADN-MIB
1.3.6.1.4.1.637.3.1.8.5adnEnvHssADN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637.3.1.8.5.1adnFranpTrunkEnvMIBADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.1.1adnFrtChanSiTableADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.1.1.1adnFrtChanSiEntryADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.1.1.1.14adnFrtChanSiMinDlyAmtADN-ENV-MIB