ADN-ENV-MIB :: adnAtmLinePerfHighSES15Thr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-ENV-MIBadnAtmLinePerfHighSES15Thr

adnAtmLinePerfHighSES15Thr

Module: ADN-ENV-MIB

OID (symbolic): ADN-ENV-MIB::adnAtmLinePerfHighSES15Thr

OID (numeric): 1.3.6.1.4.1.637.3.1.8.5.5.23.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This indicates the high threshold for severely errored second on 1/4 hour period; the value range of this threshold is 0..900.

What is adnAtmLinePerfHighSES15Thr?

ADN-ENV-MIB::adnAtmLinePerfHighSES15Thr specifies the maximum number of severely errored seconds allowed in a 15-minute interval; exceeding this indicates unacceptable service quality. Network operators monitor this to identify when lines are becoming unreliable enough to schedule maintenance or trigger customer notifications. Setting it to 5 means if 6 seconds have severe errors in a quarter-hour, the line is flagged as seriously degraded.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.23.1.10
snmpwalk -v2c -c public <target> ADN-ENV-MIB::adnAtmLinePerfHighSES15Thr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.23.1.10.1
snmpget -v2c -c public <target> ADN-ENV-MIB::adnAtmLinePerfHighSES15Thr.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.637.3.1.8.5.5.23.1.10.1 i <value>

Start monitoring Frame Relay access equipment (FRANP signalling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-ENV-MIB::adnAtmLinePerfHighSES15Thr OID value, configure state conditions and alerts, and monitor any Frame Relay access equipment (FRANP signalling) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.8adnEnvironmentADN-MIB
1.3.6.1.4.1.637.3.1.8.5adnEnvHssADN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637.3.1.8.5.5adnNodeSupervisionEnvMIBADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.23adnAtmLinePerfTableADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.23.1adnAtmLinePerfEntryADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.23.1.10adnAtmLinePerfHighSES15ThrADN-ENV-MIB