ADN-ENV-MIB :: adnAtmLinePerfConsSeverErrSec

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-ENV-MIBadnAtmLinePerfConsSeverErrSec

adnAtmLinePerfConsSeverErrSec

Module: ADN-ENV-MIB

OID (symbolic): ADN-ENV-MIB::adnAtmLinePerfConsSeverErrSec

OID (numeric): 1.3.6.1.4.1.637.3.1.8.5.5.23.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This indicates the number of consecutive severely errored seconds used for the F3 maintenance flow calculation.

What is adnAtmLinePerfConsSeverErrSec?

ADN-ENV-MIB::adnAtmLinePerfConsSeverErrSec defines how many consecutive severely errored seconds are counted to calculate F3 maintenance signals, which are used for path-level fault detection. Network engineers configure this to adjust how quickly the system detects path-level faults and triggers protective actions on the ATM path. Setting it to 2 means F3 faults are generated after just 2 seconds of severe errors, allowing faster fault isolation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.23.1.7
snmpwalk -v2c -c public <target> ADN-ENV-MIB::adnAtmLinePerfConsSeverErrSec

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.23.1.7.1
snmpget -v2c -c public <target> ADN-ENV-MIB::adnAtmLinePerfConsSeverErrSec.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.637.3.1.8.5.5.23.1.7.1 i <value>

Start monitoring Frame Relay access equipment (FRANP signalling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-ENV-MIB::adnAtmLinePerfConsSeverErrSec OID value, configure state conditions and alerts, and monitor any Frame Relay access equipment (FRANP signalling) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.8adnEnvironmentADN-MIB
1.3.6.1.4.1.637.3.1.8.5adnEnvHssADN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637.3.1.8.5.5adnNodeSupervisionEnvMIBADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.23adnAtmLinePerfTableADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.23.1adnAtmLinePerfEntryADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.23.1.7adnAtmLinePerfConsSeverErrSecADN-ENV-MIB