ADN-ENV-MIB :: adnAtmLineDefSignalling

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-ENV-MIBadnAtmLineDefSignalling

adnAtmLineDefSignalling

Module: ADN-ENV-MIB

OID (symbolic): ADN-ENV-MIB::adnAtmLineDefSignalling

OID (numeric): 1.3.6.1.4.1.637.3.1.8.5.5.22.1.12

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This indicates the failure signalling in addition to the report towards the control unit (CU). It is coded as a bit map. The various bit positions are:

1 : ERI (error indicator, bit inserted in the active maintenance cells to warn neighbour boards that an error is detected), 2 : P-FERF or RDI-P (path section far end received failure indication sent to the origin of the defect), 4 : MS-FERF or RDI-L (multiplexing section far end received failure indication sent to the origin of the defect), 8 : ATM-AIS (alarm indication signal is sent on a line defect towards the network handler dealing with VP/VC AIS management), 16 : RAI (remote alarm indication), 32 : RLED (the status led must be set permanent red).

What is adnAtmLineDefSignalling?

This OID is a bitmap that defines which failure signals are sent to the control unit—for example, ERI (error indicator) to warn neighboring boards or P-FERF to indicate far-end failures. This is read-only because signalling behavior is defined by the ATM standards rather than runtime configuration. A value of 6 might indicate that both path and circuit-level signalling are enabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.22.1.12
snmpwalk -v2c -c public <target> ADN-ENV-MIB::adnAtmLineDefSignalling

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.22.1.12.1
snmpget -v2c -c public <target> ADN-ENV-MIB::adnAtmLineDefSignalling.1

Start monitoring Frame Relay access equipment (FRANP signalling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-ENV-MIB::adnAtmLineDefSignalling OID value, configure state conditions and alerts, and monitor any Frame Relay access equipment (FRANP signalling) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.8adnEnvironmentADN-MIB
1.3.6.1.4.1.637.3.1.8.5adnEnvHssADN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637.3.1.8.5.5adnNodeSupervisionEnvMIBADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.22adnAtmLineDefTableADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.22.1adnAtmLineDefEntryADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.22.1.12adnAtmLineDefSignallingADN-ENV-MIB