ADN-ENV-MIB :: adnAtmLineDefFailureSig

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-ENV-MIBadnAtmLineDefFailureSig

adnAtmLineDefFailureSig

Module: ADN-ENV-MIB

OID (symbolic): ADN-ENV-MIB::adnAtmLineDefFailureSig

OID (numeric): 1.3.6.1.4.1.637.3.1.8.5.5.22.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This indicates the failure signalling in addition to the report towards the control unit (CU). It is coded as a bit map. The various bit positions are:

1 : ERI or RSA (error indicator, bit inserted in theactive maintenance cells to warn neighbour boards that an error is detected), 2 : P-FERF or RDI-P or RAI (path section far end received failure indication sent to the origin of the defect), 4 : MS-FERF or RDI-L (multiplexing section far end received failure indication sent to the origin of the defect), 8 : ATM-AIS (alarm indication signal is sent on a line defect towards the network handler dealing with VP/VC AIS management), 32 : RLED (the status led must be set permanent red).

What is adnAtmLineDefFailureSig?

ADN-ENV-MIB::adnAtmLineDefFailureSig is a bitmap that configures which ATM failure signals (like error indicators or far-end failure notifications) are sent to neighboring equipment. Network engineers set this to control how defects propagate through the ATM network—determining which alarm signals reach upstream and downstream devices. Setting bit 1 active (value 1) tells neighbor cards there is an error, while bit 2 active (value 2) sends upstream failure notifications.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.22.1.17
snmpwalk -v2c -c public <target> ADN-ENV-MIB::adnAtmLineDefFailureSig

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.22.1.17.1
snmpget -v2c -c public <target> ADN-ENV-MIB::adnAtmLineDefFailureSig.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.637.3.1.8.5.5.22.1.17.1 i <value>

Start monitoring Frame Relay access equipment (FRANP signalling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-ENV-MIB::adnAtmLineDefFailureSig OID value, configure state conditions and alerts, and monitor any Frame Relay access equipment (FRANP signalling) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.8adnEnvironmentADN-MIB
1.3.6.1.4.1.637.3.1.8.5adnEnvHssADN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637.3.1.8.5.5adnNodeSupervisionEnvMIBADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.22adnAtmLineDefTableADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.22.1adnAtmLineDefEntryADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.22.1.17adnAtmLineDefFailureSigADN-ENV-MIB