All MIBs › ADN-ENV-MIB › adnAtmLineDefBegTimer
adnAtmLineDefBegTimer
Module: ADN-ENV-MIB
OID (symbolic): ADN-ENV-MIB::adnAtmLineDefBegTimer
OID (numeric): 1.3.6.1.4.1.637.3.1.8.5.5.22.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This indicates the beginning timer in milliseconds during which the first appearance of an error is controlled.
What is adnAtmLineDefBegTimer?
This OID holds the time window in milliseconds the system watches for the beginning of defects on the ATM line before deciding if an alarm should be raised. This window smooths out transient glitches and gives a more stable picture of line health. A value of 500 milliseconds creates a half-second observation window so occasional bit flips don't trigger unnecessary alerts.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.22.1.10 snmpwalk -v2c -c public <target> ADN-ENV-MIB::adnAtmLineDefBegTimer
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.22.1.10.1 snmpget -v2c -c public <target> ADN-ENV-MIB::adnAtmLineDefBegTimer.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.637.3.1.8.5.5.22.1.10.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> adnAtmLineDefBegTimer.1
Start monitoring Frame Relay access equipment (FRANP signalling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-ENV-MIB::adnAtmLineDefBegTimer OID value, configure state conditions and alerts, and monitor any Frame Relay access equipment (FRANP signalling) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.637 | alcatel | ADN-MIB |
| 1.3.6.1.4.1.637.3 | adn | ADN-MIB |
| 1.3.6.1.4.1.637.3.1 | adnMIB | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.8 | adnEnvironment | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.8.5 | adnEnvHss | ADN-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.637.3.1.8.5.5 | adnNodeSupervisionEnvMIB | ADN-ENV-MIB |
| 1.3.6.1.4.1.637.3.1.8.5.5.22 | adnAtmLineDefTable | ADN-ENV-MIB |
| 1.3.6.1.4.1.637.3.1.8.5.5.22.1 | adnAtmLineDefEntry | ADN-ENV-MIB |
| 1.3.6.1.4.1.637.3.1.8.5.5.22.1.10 | adnAtmLineDefBegTimer | ADN-ENV-MIB |