ADN-ENV-MIB :: adnAeiPortDefEventClass

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-ENV-MIBadnAeiPortDefEventClass

adnAeiPortDefEventClass

Module: ADN-ENV-MIB

OID (symbolic): ADN-ENV-MIB::adnAeiPortDefEventClass

OID (numeric): 1.3.6.1.4.1.637.3.1.8.5.5.21.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This indicates the event class from hardware side:

event: single fault signalled by the hardware or another software module to the supervision antenna inside the coupler board. No end is signalled, the presence of the fault can't be checked.

status: the beginning of the fault is signalled to the supervision antenna inside the coupler board; the presence of the fault can be checked.

statusc: the hardware provides no interrupt; this status is periodically scanned by the supervision antenna inside the coupler board.

counter: a n bit long hardware counter counts the elementary events; an interrupt is generally sent at saturation; its value can be read; it is reset to zero when read.

What is adnAeiPortDefEventClass?

This read-only value indicates whether the port defect is a one-time event, a trackable status condition, or a condition that lacks hardware interrupts. Network engineers interpret this to decide whether the defect needs immediate investigation, can be monitored passively, or is likely a status artifact. An 'event' classification means only one fault signal was sent with no recovery signal, while 'status' means the fault onset was signaled and can be monitored until cleared.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.21.1.3
snmpwalk -v2c -c public <target> ADN-ENV-MIB::adnAeiPortDefEventClass

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.8.5.5.21.1.3.1
snmpget -v2c -c public <target> ADN-ENV-MIB::adnAeiPortDefEventClass.1

Start monitoring Frame Relay access equipment (FRANP signalling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-ENV-MIB::adnAeiPortDefEventClass OID value, configure state conditions and alerts, and monitor any Frame Relay access equipment (FRANP signalling) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.8adnEnvironmentADN-MIB
1.3.6.1.4.1.637.3.1.8.5adnEnvHssADN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637.3.1.8.5.5adnNodeSupervisionEnvMIBADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.21adnAeiPortDefTableADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.21.1adnAeiPortDefEntryADN-ENV-MIB
1.3.6.1.4.1.637.3.1.8.5.5.21.1.3adnAeiPortDefEventClassADN-ENV-MIB