ADIC-SANMGR-PROXY-MIB :: scsiAlternateHostId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADIC-SANMGR-PROXY-MIBscsiAlternateHostId

scsiAlternateHostId

Module: ADIC-SANMGR-PROXY-MIB

OID (symbolic): ADIC-SANMGR-PROXY-MIB::scsiAlternateHostId

OID (numeric): 1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.15

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Alternate Host ID for this SCSI controller. -1 means use automatic.

What is scsiAlternateHostId?

This OID specifies a backup SCSI ID the controller uses if the primary ID becomes unavailable, with -1 selecting automatic failover. Network engineers configure this for high-availability clusters where a controller might need to switch identities without losing connectivity to shared devices. For example, setting scsiAlternateHostId to 5 provides ID 5 as a backup if the primary ID becomes unusable or is claimed by another device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.15
snmpwalk -v2c -c public <target> ADIC-SANMGR-PROXY-MIB::scsiAlternateHostId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.15.1
snmpget -v2c -c public <target> ADIC-SANMGR-PROXY-MIB::scsiAlternateHostId.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.15.1 i <value>

Start monitoring ADIC (Quantum) tape libraries with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-SANMGR-PROXY-MIB::scsiAlternateHostId OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) tape libraries from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3764adicADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1storageADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1intelligentADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.400networkADIC-INTELLIGENT-STORAGE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3764.1.1.400.10sanmgr_proxyADIC-SANMGR-PROXY-MIB
1.3.6.1.4.1.3764.1.1.400.10.10pathlightADIC-SANMGR-PROXY-MIB
1.3.6.1.4.1.3764.1.1.400.10.10.4controllersADIC-SANMGR-PROXY-MIB
1.3.6.1.4.1.3764.1.1.400.10.10.4.4pcSCSICtlrsADIC-SANMGR-PROXY-MIB
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1scsiCtlrEntryADIC-SANMGR-PROXY-MIB
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.15scsiAlternateHostIdADIC-SANMGR-PROXY-MIB