Description: Host type for this port. Used if VPS is not enabled.
What is pcPortHostType?
This string (up to 32 characters) identifies the operating system or host type connected to this controller port, used only when Virtual Port Server auto-detection is disabled. You manually set this value when using legacy host type detection that requires explicit configuration instead of automatic negotiation. An example value of "Solaris" tells the controller that a Sun Solaris system is connected on that port.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.24 snmpwalk -v2c -c public <target> ADIC-SANMGR-PROXY-MIB::pcPortHostType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.24.1 snmpget -v2c -c public <target> ADIC-SANMGR-PROXY-MIB::pcPortHostType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.24.1 s <value>
Start monitoring ADIC (Quantum) tape libraries with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-SANMGR-PROXY-MIB::pcPortHostType OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) tape libraries from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.400 | network | ADIC-INTELLIGENT-STORAGE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764.1.1.400.10 | sanmgr_proxy | ADIC-SANMGR-PROXY-MIB |
| 1.3.6.1.4.1.3764.1.1.400.10.10 | pathlight | ADIC-SANMGR-PROXY-MIB |
| 1.3.6.1.4.1.3764.1.1.400.10.10.4 | controllers | ADIC-SANMGR-PROXY-MIB |
| 1.3.6.1.4.1.3764.1.1.400.10.10.4.1 | pcControllers | ADIC-SANMGR-PROXY-MIB |
| 1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1 | pcCtlrEntry | ADIC-SANMGR-PROXY-MIB |
| 1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.24 | pcPortHostType | ADIC-SANMGR-PROXY-MIB |