All MIBs › AC-SS7-MIB › acSS7SignalingNodeTimersT25ANSI
acSS7SignalingNodeTimersT25ANSI
Module: AC-SS7-MIB
OID (symbolic): AC-SS7-MIB::acSS7SignalingNodeTimersT25ANSI
OID (numeric): 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.20
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: Timer at SP adjacent to restarting SP waiting for traffic restart allowed message. Access: Online. AC INI-Param: SS7_SNTIMERS_T25_ANSI
What is acSS7SignalingNodeTimersT25ANSI?
Sets the timeout window for adjacent signaling points awaiting the traffic restart allowed message from a restarting neighbor node. This prevents indefinite hangs if the restarting node fails to complete its restart sequence. Typical values like 15000 milliseconds allow reasonable recovery time without excessive delays.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.20 snmpwalk -v2c -c public <target> AC-SS7-MIB::acSS7SignalingNodeTimersT25ANSI
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.20.1 snmpget -v2c -c public <target> AC-SS7-MIB::acSS7SignalingNodeTimersT25ANSI.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.20.1 i <value>
Start monitoring AudioCodes gateways (SS7 signaling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AC-SS7-MIB::acSS7SignalingNodeTimersT25ANSI OID value, configure state conditions and alerts, and monitor any AudioCodes gateways (SS7 signaling) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5003 | audioCodes | AC-ATM-MIB |
| 1.3.6.1.4.1.5003.9 | acProducts | AC-ATM-MIB |
| 1.3.6.1.4.1.5003.9.10 | acBoardMibs | AC-ATM-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5003.9.10.12 | acSS7 | AC-SS7-MIB |
| 1.3.6.1.4.1.5003.9.10.12.1 | acSS7Configuration | AC-SS7-MIB |
| 1.3.6.1.4.1.5003.9.10.12.1.2 | acSS7Timers | AC-SS7-MIB |
| 1.3.6.1.4.1.5003.9.10.12.1.2.21 | acSS7SignalingNodeTimersTable | AC-SS7-MIB |
| 1.3.6.1.4.1.5003.9.10.12.1.2.21.1 | acSS7SignalingNodeTimersEntry | AC-SS7-MIB |
| 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.20 | acSS7SignalingNodeTimersT25ANSI | AC-SS7-MIB |