All MIBs › AC-SS7-MIB › acSS7RedundancyKeepAliveInterval
acSS7RedundancyKeepAliveInterval
Module: AC-SS7-MIB
OID (symbolic): AC-SS7-MIB::acSS7RedundancyKeepAliveInterval
OID (numeric): 1.3.6.1.4.1.5003.9.10.12.1.6.9
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: Defines redundancy X-link keep-alive interval in secs. (x-link between boards in Signaling System 7 (SS7) MTP3-User Adaptation Layer redundancy mode). 0 = no keep-alive mechanism is activated. . Access: Offline. AC INI-Param: SS7MTP3RdcyKeepAliveInterval
What is acSS7RedundancyKeepAliveInterval?
AC-SS7-MIB::acSS7RedundancyKeepAliveInterval sets how often boards send heartbeats to check if their redundancy partners are alive, in seconds (0-100). You set it to 5-10 seconds for responsive failover, or 0 to disable keep-alive entirely. For example, 5 seconds means boards exchange a health check every 5 seconds; if 3 checks are missed the link is declared dead.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5003.9.10.12.1.6.9 snmpwalk -v2c -c public <target> AC-SS7-MIB::acSS7RedundancyKeepAliveInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5003.9.10.12.1.6.9.1 snmpget -v2c -c public <target> AC-SS7-MIB::acSS7RedundancyKeepAliveInterval.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5003.9.10.12.1.6.9.1 i <value>
Start monitoring AudioCodes gateways (SS7 signaling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AC-SS7-MIB::acSS7RedundancyKeepAliveInterval OID value, configure state conditions and alerts, and monitor any AudioCodes gateways (SS7 signaling) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5003 | audioCodes | AC-ATM-MIB |
| 1.3.6.1.4.1.5003.9 | acProducts | AC-ATM-MIB |
| 1.3.6.1.4.1.5003.9.10 | acBoardMibs | AC-ATM-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5003.9.10.12 | acSS7 | AC-SS7-MIB |
| 1.3.6.1.4.1.5003.9.10.12.1 | acSS7Configuration | AC-SS7-MIB |
| 1.3.6.1.4.1.5003.9.10.12.1.6 | acSS7Redundancy | AC-SS7-MIB |
| 1.3.6.1.4.1.5003.9.10.12.1.6.9 | acSS7RedundancyKeepAliveInterval | AC-SS7-MIB |