Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is AC-PM-SS7-MIB?
AC-PM-SS7-MIB is a vendor performance-monitoring MIB from AudioCodes covering SS7 (Signaling System 7) signaling elements on gateway platforms equipped with SS7 interface cards, structured into a configuration subtree (interval period and per-table thresholds) and a data subtree of monitored performance counters. It exposes SS7 performance categories such as MTP (Message Transfer Part) and ISUP (ISDN User Part) message throughput and error-rate statistics over configurable polling intervals. This MIB is used to monitor signaling-link software/hardware performance: rising MTP error rates or falling ISUP message throughput on a link reveals a degrading SS7 signaling link or an overloaded SS7 card before call setup failures become widespread. Like its ATM counterpart, it documents a -1 sentinel value across the MIB meaning the requested statistic is unsupported or the interval hasn't yet been recorded. It is deployed on AudioCodes gateways with SS7 signaling cards in carrier or PSTN-interconnect environments where signaling-link quality directly affects call completion rates, and engineers can download the AC-PM-SS7-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in AC-PM-SS7-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- AudioCodes gateway (SS7 signaling card)
Monitoring Examples
No concrete sample objects were supplied for this module, so specific table/object names cannot be grounded; conceptually an administrator would poll interval-based MTP/ISUP throughput and error-rate counters from the data subtree, treating the documented -1 sentinel as 'unsupported or not yet recorded' rather than a real zero, but naming exact objects here would be speculative.
This MIB depends on
Related MIBs
Imported Objects
From AUDIOCODES-TYPES-MIB
| acBoardMibs | OBJECT-IDENTITY |
| acGeneric | OBJECT-IDENTITY |
| acPerformance | OBJECT-IDENTITY |
| acProducts | OBJECT-IDENTITY |
| acRegistrations | OBJECT-IDENTITY |
| audioCodes | OBJECT-IDENTITY |
From RFC1155-SMI
| IpAddress |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 | |
| enterprises |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| TAddress | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| acPMSS7 | 1.3.6.1.4.1.5003.10.13 | The AC-PM-SS7 MIB offers performance monitoring For the SS7 related elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-SS7 MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded. | ||
| acPMSS7Configuration | 1.3.6.1.4.1.5003.10.13.1 | |||
| U32 acPMSS7ConfigurationPeriodLength | 1.3.6.1.4.1.5003.10.13.1.1 | Unsigned32 | read-write | Length of monitoring intervals for entire MIB. Time is in minutes. Access: Online. |
| INT acPMSS7ConfigurationResetTotalCounters | 1.3.6.1.4.1.5003.10.13.1.2 | INTEGER | read-write | Total-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2). Access: Online. |
| acPMSS7Data | 1.3.6.1.4.1.5003.10.13.2 | |||
| U32 acPMSS7DataTimeFromStartOfInterval | 1.3.6.1.4.1.5003.10.13.2.1 | Unsigned32 | read-only | The time in seconds since the start of the current interval. MIB specific. |
| acPMSS7DiscMSUEntry | 1.3.6.1.4.1.5003.10.13.2.31.12.1 | not-accessible | ||
| U32 acPMSS7DiscMSUInterval | 1.3.6.1.4.1.5003.10.13.2.31.12.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7DiscMSULink | 1.3.6.1.4.1.5003.10.13.2.31.12.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7DiscMSUTable | 1.3.6.1.4.1.5003.10.13.2.31.12 | not-accessible | MSUs discarded due to SL congestion - transmit and receive - Q.752 3.10 | |
| I32 acPMSS7DiscMSUTotal | 1.3.6.1.4.1.5003.10.13.2.31.12.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7DiscMSUVal | 1.3.6.1.4.1.5003.10.13.2.31.12.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7InServiceEntry | 1.3.6.1.4.1.5003.10.13.2.31.13.1 | not-accessible | ||
| U32 acPMSS7InServiceInterval | 1.3.6.1.4.1.5003.10.13.2.31.13.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7InServiceLink | 1.3.6.1.4.1.5003.10.13.2.31.13.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7InServiceTable | 1.3.6.1.4.1.5003.10.13.2.31.13 | not-accessible | Duration of SS7 link at in-service state in percentage (in last 30 minutes) - Q.752 1.1 | |
| I32 acPMSS7InServiceTimeAboveHighThreshold | 1.3.6.1.4.1.5003.10.13.2.31.13.1.4 | Integer32 | read-only | Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'In Service'. |
| I32 acPMSS7InServiceTimeBetweenThresholds | 1.3.6.1.4.1.5003.10.13.2.31.13.1.5 | Integer32 | read-only | Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'In Service'. |
| G32 acPMSS7InServiceVal | 1.3.6.1.4.1.5003.10.13.2.31.13.1.3 | Gauge32 | read-only | Value of gauge or counter. |
| acPMSS7Links | 1.3.6.1.4.1.5003.10.13.2.31 | |||
| acPMSS7LinkSets | 1.3.6.1.4.1.5003.10.13.2.41 | |||
| acPMSS7MPT2Timers | 1.3.6.1.4.1.5003.10.13.2.61 | |||
| acPMSS7MTP2NoAckRxEntry | 1.3.6.1.4.1.5003.10.13.2.31.11.1 | not-accessible | ||
| U32 acPMSS7MTP2NoAckRxInterval | 1.3.6.1.4.1.5003.10.13.2.31.11.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP2NoAckRxLink | 1.3.6.1.4.1.5003.10.13.2.31.11.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7MTP2NoAckRxTable | 1.3.6.1.4.1.5003.10.13.2.31.11 | not-accessible | Number of MTP2 Not Ack received (from far end) per SS7 link - Q.752 1.9 | |
| I32 acPMSS7MTP2NoAckRxTotal | 1.3.6.1.4.1.5003.10.13.2.31.11.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP2NoAckRxVal | 1.3.6.1.4.1.5003.10.13.2.31.11.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7MTP2T1ExpiryEntry | 1.3.6.1.4.1.5003.10.13.2.61.1.1 | not-accessible | ||
| U32 acPMSS7MTP2T1ExpiryInterval | 1.3.6.1.4.1.5003.10.13.2.61.1.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP2T1ExpiryLink | 1.3.6.1.4.1.5003.10.13.2.61.1.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7MTP2T1ExpiryTable | 1.3.6.1.4.1.5003.10.13.2.61.1 | not-accessible | Number of MTP2 T1 expiry per SS7 link | |
| I32 acPMSS7MTP2T1ExpiryTotal | 1.3.6.1.4.1.5003.10.13.2.61.1.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP2T1ExpiryVal | 1.3.6.1.4.1.5003.10.13.2.61.1.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7MTP2T2ExpiryEntry | 1.3.6.1.4.1.5003.10.13.2.61.2.1 | not-accessible | ||
| U32 acPMSS7MTP2T2ExpiryInterval | 1.3.6.1.4.1.5003.10.13.2.61.2.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP2T2ExpiryLink | 1.3.6.1.4.1.5003.10.13.2.61.2.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7MTP2T2ExpiryTable | 1.3.6.1.4.1.5003.10.13.2.61.2 | not-accessible | Number of MTP2 T2 expiry per SS7 link | |
| I32 acPMSS7MTP2T2ExpiryTotal | 1.3.6.1.4.1.5003.10.13.2.61.2.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP2T2ExpiryVal | 1.3.6.1.4.1.5003.10.13.2.61.2.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7MTP2T3ExpiryEntry | 1.3.6.1.4.1.5003.10.13.2.61.3.1 | not-accessible | ||
| U32 acPMSS7MTP2T3ExpiryInterval | 1.3.6.1.4.1.5003.10.13.2.61.3.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP2T3ExpiryLink | 1.3.6.1.4.1.5003.10.13.2.61.3.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7MTP2T3ExpiryTable | 1.3.6.1.4.1.5003.10.13.2.61.3 | not-accessible | Number of MTP2 T3 expiry per SS7 link | |
| I32 acPMSS7MTP2T3ExpiryTotal | 1.3.6.1.4.1.5003.10.13.2.61.3.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP2T3ExpiryVal | 1.3.6.1.4.1.5003.10.13.2.61.3.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7MTP2T4ExpiryEntry | 1.3.6.1.4.1.5003.10.13.2.61.4.1 | not-accessible | ||
| U32 acPMSS7MTP2T4ExpiryInterval | 1.3.6.1.4.1.5003.10.13.2.61.4.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP2T4ExpiryLink | 1.3.6.1.4.1.5003.10.13.2.61.4.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7MTP2T4ExpiryTable | 1.3.6.1.4.1.5003.10.13.2.61.4 | not-accessible | Number of MTP2 T4 expiry per SS7 link | |
| I32 acPMSS7MTP2T4ExpiryTotal | 1.3.6.1.4.1.5003.10.13.2.61.4.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP2T4ExpiryVal | 1.3.6.1.4.1.5003.10.13.2.61.4.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7MTP2T5ExpiryEntry | 1.3.6.1.4.1.5003.10.13.2.61.5.1 | not-accessible | ||
| U32 acPMSS7MTP2T5ExpiryInterval | 1.3.6.1.4.1.5003.10.13.2.61.5.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP2T5ExpiryLink | 1.3.6.1.4.1.5003.10.13.2.61.5.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7MTP2T5ExpiryTable | 1.3.6.1.4.1.5003.10.13.2.61.5 | not-accessible | Number of MTP2 T5 expiry per SS7 link | |
| I32 acPMSS7MTP2T5ExpiryTotal | 1.3.6.1.4.1.5003.10.13.2.61.5.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP2T5ExpiryVal | 1.3.6.1.4.1.5003.10.13.2.61.5.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7MTP2T6ExpiryEntry | 1.3.6.1.4.1.5003.10.13.2.61.6.1 | not-accessible | ||
| U32 acPMSS7MTP2T6ExpiryInterval | 1.3.6.1.4.1.5003.10.13.2.61.6.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP2T6ExpiryLink | 1.3.6.1.4.1.5003.10.13.2.61.6.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7MTP2T6ExpiryTable | 1.3.6.1.4.1.5003.10.13.2.61.6 | not-accessible | Number of MTP2 T6 expiry per SS7 link | |
| I32 acPMSS7MTP2T6ExpiryTotal | 1.3.6.1.4.1.5003.10.13.2.61.6.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP2T6ExpiryVal | 1.3.6.1.4.1.5003.10.13.2.61.6.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7MTP2T7ExpiryEntry | 1.3.6.1.4.1.5003.10.13.2.61.7.1 | not-accessible | ||
| U32 acPMSS7MTP2T7ExpiryInterval | 1.3.6.1.4.1.5003.10.13.2.61.7.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP2T7ExpiryLink | 1.3.6.1.4.1.5003.10.13.2.61.7.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7MTP2T7ExpiryTable | 1.3.6.1.4.1.5003.10.13.2.61.7 | not-accessible | Number of MTP2 T7 expiry per SS7 link | |
| I32 acPMSS7MTP2T7ExpiryTotal | 1.3.6.1.4.1.5003.10.13.2.61.7.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP2T7ExpiryVal | 1.3.6.1.4.1.5003.10.13.2.61.7.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7MTP3MSUDiscardedEntry | 1.3.6.1.4.1.5003.10.13.2.51.7.1 | not-accessible | ||
| U32 acPMSS7MTP3MSUDiscardedInterval | 1.3.6.1.4.1.5003.10.13.2.51.7.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| acPMSS7MTP3MSUDiscardedRtDataErrEntry | 1.3.6.1.4.1.5003.10.13.2.51.8.1 | not-accessible | ||
| U32 acPMSS7MTP3MSUDiscardedRtDataErrInterval | 1.3.6.1.4.1.5003.10.13.2.51.8.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7MTP3MSUDiscardedRtDataErrSN | 1.3.6.1.4.1.5003.10.13.2.51.8.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7MTP3MSUDiscardedRtDataErrTable | 1.3.6.1.4.1.5003.10.13.2.51.8 | not-accessible | Number of MTP3 Msu's discarded Due to Routing Data error per SS7 MTP3 node - Q.752 5.5 | |
| I32 acPMSS7MTP3MSUDiscardedRtDataErrTotal | 1.3.6.1.4.1.5003.10.13.2.51.8.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP3MSUDiscardedRtDataErrVal | 1.3.6.1.4.1.5003.10.13.2.51.8.1.3 | Counter32 | read-only | Value of gauge or counter. |
| U32 acPMSS7MTP3MSUDiscardedSN | 1.3.6.1.4.1.5003.10.13.2.51.7.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7MTP3MSUDiscardedTable | 1.3.6.1.4.1.5003.10.13.2.51.7 | not-accessible | Number of discarded MTP3 MSU's per SS7 MTP3 node | |
| I32 acPMSS7MTP3MSUDiscardedTotal | 1.3.6.1.4.1.5003.10.13.2.51.7.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7MTP3MSUDiscardedVal | 1.3.6.1.4.1.5003.10.13.2.51.7.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7OutOfServiceEntry | 1.3.6.1.4.1.5003.10.13.2.31.14.1 | not-accessible | ||
| U32 acPMSS7OutOfServiceInterval | 1.3.6.1.4.1.5003.10.13.2.31.14.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7OutOfServiceLink | 1.3.6.1.4.1.5003.10.13.2.31.14.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7OutOfServiceTable | 1.3.6.1.4.1.5003.10.13.2.31.14 | not-accessible | Duration of SS7 link at out-of-service state in percentage (in last 30 minutes) - Q.752 2.1 | |
| I32 acPMSS7OutOfServiceTimeAboveHighThreshold | 1.3.6.1.4.1.5003.10.13.2.31.14.1.4 | Integer32 | read-only | Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'. |
| I32 acPMSS7OutOfServiceTimeBetweenThresholds | 1.3.6.1.4.1.5003.10.13.2.31.14.1.5 | Integer32 | read-only | Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'. |
| G32 acPMSS7OutOfServiceVal | 1.3.6.1.4.1.5003.10.13.2.31.14.1.3 | Gauge32 | read-only | Value of gauge or counter. |
| acPMSS7RxFISUEntry | 1.3.6.1.4.1.5003.10.13.2.31.6.1 | not-accessible | ||
| U32 acPMSS7RxFISUInterval | 1.3.6.1.4.1.5003.10.13.2.31.6.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxFISULink | 1.3.6.1.4.1.5003.10.13.2.31.6.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7RxFISUTable | 1.3.6.1.4.1.5003.10.13.2.31.6 | not-accessible | Number of received FISU's per SS7 link. | |
| I32 acPMSS7RxFISUTotal | 1.3.6.1.4.1.5003.10.13.2.31.6.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxFISUVal | 1.3.6.1.4.1.5003.10.13.2.31.6.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7RxLSSUEntry | 1.3.6.1.4.1.5003.10.13.2.31.4.1 | not-accessible | ||
| U32 acPMSS7RxLSSUInterval | 1.3.6.1.4.1.5003.10.13.2.31.4.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxLSSULink | 1.3.6.1.4.1.5003.10.13.2.31.4.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7RxLSSUTable | 1.3.6.1.4.1.5003.10.13.2.31.4 | not-accessible | Number of received LSSU's per SS7 link. | |
| I32 acPMSS7RxLSSUTotal | 1.3.6.1.4.1.5003.10.13.2.31.4.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxLSSUVal | 1.3.6.1.4.1.5003.10.13.2.31.4.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7RxMSUEntry | 1.3.6.1.4.1.5003.10.13.2.31.2.1 | not-accessible | ||
| U32 acPMSS7RxMSUInterval | 1.3.6.1.4.1.5003.10.13.2.31.2.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxMSULink | 1.3.6.1.4.1.5003.10.13.2.31.2.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7RxMSUTable | 1.3.6.1.4.1.5003.10.13.2.31.2 | not-accessible | Number of received MSU's per SS7 link. | |
| I32 acPMSS7RxMSUTotal | 1.3.6.1.4.1.5003.10.13.2.31.2.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxMSUVal | 1.3.6.1.4.1.5003.10.13.2.31.2.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7RxMTP3MSUEntry | 1.3.6.1.4.1.5003.10.13.2.51.4.1 | not-accessible | ||
| U32 acPMSS7RxMTP3MSUInterval | 1.3.6.1.4.1.5003.10.13.2.51.4.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxMTP3MSUSN | 1.3.6.1.4.1.5003.10.13.2.51.4.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7RxMTP3MSUTable | 1.3.6.1.4.1.5003.10.13.2.51.4 | not-accessible | Number of received MTP3 MSU's per SS7 MTP3 node | |
| I32 acPMSS7RxMTP3MSUTotal | 1.3.6.1.4.1.5003.10.13.2.51.4.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxMTP3MSUVal | 1.3.6.1.4.1.5003.10.13.2.51.4.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7RxMTP3OctetsEntry | 1.3.6.1.4.1.5003.10.13.2.51.2.1 | not-accessible | ||
| U32 acPMSS7RxMTP3OctetsInterval | 1.3.6.1.4.1.5003.10.13.2.51.2.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxMTP3OctetsSN | 1.3.6.1.4.1.5003.10.13.2.51.2.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7RxMTP3OctetsTable | 1.3.6.1.4.1.5003.10.13.2.51.2 | not-accessible | Number of received MTP3 octets per SS7 MTP3 node | |
| I32 acPMSS7RxMTP3OctetsTotal | 1.3.6.1.4.1.5003.10.13.2.51.2.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxMTP3OctetsVal | 1.3.6.1.4.1.5003.10.13.2.51.2.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7RxMTP3TFCMsgEntry | 1.3.6.1.4.1.5003.10.13.2.51.9.1 | not-accessible | ||
| U32 acPMSS7RxMTP3TFCMsgInterval | 1.3.6.1.4.1.5003.10.13.2.51.9.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxMTP3TFCMsgSN | 1.3.6.1.4.1.5003.10.13.2.51.9.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7RxMTP3TFCMsgTable | 1.3.6.1.4.1.5003.10.13.2.51.9 | not-accessible | Number of MTP3 TFC messages received per SS7 MTP3 node | |
| I32 acPMSS7RxMTP3TFCMsgTotal | 1.3.6.1.4.1.5003.10.13.2.51.9.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxMTP3TFCMsgVal | 1.3.6.1.4.1.5003.10.13.2.51.9.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7RxMTP3UPUEntry | 1.3.6.1.4.1.5003.10.13.2.51.6.1 | not-accessible | ||
| U32 acPMSS7RxMTP3UPUInterval | 1.3.6.1.4.1.5003.10.13.2.51.6.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxMTP3UPUSN | 1.3.6.1.4.1.5003.10.13.2.51.6.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7RxMTP3UPUTable | 1.3.6.1.4.1.5003.10.13.2.51.6 | not-accessible | Number of received MTP3 User Part Unavailable messages per SS7 MTP3 node | |
| I32 acPMSS7RxMTP3UPUTotal | 1.3.6.1.4.1.5003.10.13.2.51.6.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxMTP3UPUVal | 1.3.6.1.4.1.5003.10.13.2.51.6.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7RxOctetsEntry | 1.3.6.1.4.1.5003.10.13.2.31.10.1 | not-accessible | ||
| U32 acPMSS7RxOctetsInterval | 1.3.6.1.4.1.5003.10.13.2.31.10.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxOctetsLink | 1.3.6.1.4.1.5003.10.13.2.31.10.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7RxOctetsTable | 1.3.6.1.4.1.5003.10.13.2.31.10 | not-accessible | Number of received Octets per SS7 link - Q.752 3.4 | |
| I32 acPMSS7RxOctetsTotal | 1.3.6.1.4.1.5003.10.13.2.31.10.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxOctetsVal | 1.3.6.1.4.1.5003.10.13.2.31.10.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7RxSignalUnitsEntry | 1.3.6.1.4.1.5003.10.13.2.31.8.1 | not-accessible | ||
| U32 acPMSS7RxSignalUnitsInterval | 1.3.6.1.4.1.5003.10.13.2.31.8.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7RxSignalUnitsLink | 1.3.6.1.4.1.5003.10.13.2.31.8.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7RxSignalUnitsTable | 1.3.6.1.4.1.5003.10.13.2.31.8 | not-accessible | Number of received Signaling units per SS7 link | |
| I32 acPMSS7RxSignalUnitsTotal | 1.3.6.1.4.1.5003.10.13.2.31.8.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7RxSignalUnitsVal | 1.3.6.1.4.1.5003.10.13.2.31.8.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7SignalingNodes | 1.3.6.1.4.1.5003.10.13.2.51 | |||
| acPMSS7SN0LSOutOfServiceEntry | 1.3.6.1.4.1.5003.10.13.2.41.1.1 | not-accessible | ||
| U32 acPMSS7SN0LSOutOfServiceInterval | 1.3.6.1.4.1.5003.10.13.2.41.1.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7SN0LSOutOfServiceLinkSet | 1.3.6.1.4.1.5003.10.13.2.41.1.1.1 | Unsigned32 | not-accessible | Link Set number. 0 is the first link. |
| acPMSS7SN0LSOutOfServiceTable | 1.3.6.1.4.1.5003.10.13.2.41.1 | not-accessible | Duration of SS7 linkSet within Signaling node 0 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2 | |
| I32 acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold | 1.3.6.1.4.1.5003.10.13.2.41.1.1.4 | Integer32 | read-only | Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'. |
| I32 acPMSS7SN0LSOutOfServiceTimeBetweenThresholds | 1.3.6.1.4.1.5003.10.13.2.41.1.1.5 | Integer32 | read-only | Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'. |
| G32 acPMSS7SN0LSOutOfServiceVal | 1.3.6.1.4.1.5003.10.13.2.41.1.1.3 | Gauge32 | read-only | Value of gauge or counter. |
| acPMSS7SN1LSOutOfServiceEntry | 1.3.6.1.4.1.5003.10.13.2.41.2.1 | not-accessible | ||
| U32 acPMSS7SN1LSOutOfServiceInterval | 1.3.6.1.4.1.5003.10.13.2.41.2.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7SN1LSOutOfServiceLinkSet | 1.3.6.1.4.1.5003.10.13.2.41.2.1.1 | Unsigned32 | not-accessible | Link Set number. 0 is the first link. |
| acPMSS7SN1LSOutOfServiceTable | 1.3.6.1.4.1.5003.10.13.2.41.2 | not-accessible | Duration of SS7 linkSet within Signaling node 1 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2 | |
| I32 acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold | 1.3.6.1.4.1.5003.10.13.2.41.2.1.4 | Integer32 | read-only | Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'. |
| I32 acPMSS7SN1LSOutOfServiceTimeBetweenThresholds | 1.3.6.1.4.1.5003.10.13.2.41.2.1.5 | Integer32 | read-only | Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'. |
| G32 acPMSS7SN1LSOutOfServiceVal | 1.3.6.1.4.1.5003.10.13.2.41.2.1.3 | Gauge32 | read-only | Value of gauge or counter. |
| acPMSS7TxFISUEntry | 1.3.6.1.4.1.5003.10.13.2.31.5.1 | not-accessible | ||
| U32 acPMSS7TxFISUInterval | 1.3.6.1.4.1.5003.10.13.2.31.5.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7TxFISULink | 1.3.6.1.4.1.5003.10.13.2.31.5.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7TxFISUTable | 1.3.6.1.4.1.5003.10.13.2.31.5 | not-accessible | Number of transmitted FISU's per SS7 link. | |
| I32 acPMSS7TxFISUTotal | 1.3.6.1.4.1.5003.10.13.2.31.5.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7TxFISUVal | 1.3.6.1.4.1.5003.10.13.2.31.5.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7TxLSSUEntry | 1.3.6.1.4.1.5003.10.13.2.31.3.1 | not-accessible | ||
| U32 acPMSS7TxLSSUInterval | 1.3.6.1.4.1.5003.10.13.2.31.3.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7TxLSSULink | 1.3.6.1.4.1.5003.10.13.2.31.3.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7TxLSSUTable | 1.3.6.1.4.1.5003.10.13.2.31.3 | not-accessible | Number of transmitted LSSU's per SS7 link. | |
| I32 acPMSS7TxLSSUTotal | 1.3.6.1.4.1.5003.10.13.2.31.3.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7TxLSSUVal | 1.3.6.1.4.1.5003.10.13.2.31.3.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7TxMSUEntry | 1.3.6.1.4.1.5003.10.13.2.31.1.1 | not-accessible | ||
| U32 acPMSS7TxMSUInterval | 1.3.6.1.4.1.5003.10.13.2.31.1.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7TxMSULink | 1.3.6.1.4.1.5003.10.13.2.31.1.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7TxMSUTable | 1.3.6.1.4.1.5003.10.13.2.31.1 | not-accessible | Number of transmitted MSU's per SS7 link. | |
| I32 acPMSS7TxMSUTotal | 1.3.6.1.4.1.5003.10.13.2.31.1.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7TxMSUVal | 1.3.6.1.4.1.5003.10.13.2.31.1.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7TxMTP3MSUEntry | 1.3.6.1.4.1.5003.10.13.2.51.3.1 | not-accessible | ||
| U32 acPMSS7TxMTP3MSUInterval | 1.3.6.1.4.1.5003.10.13.2.51.3.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7TxMTP3MSUSN | 1.3.6.1.4.1.5003.10.13.2.51.3.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7TxMTP3MSUTable | 1.3.6.1.4.1.5003.10.13.2.51.3 | not-accessible | Number of transmitted MTP3 MSU's per SS7 MTP3 node | |
| I32 acPMSS7TxMTP3MSUTotal | 1.3.6.1.4.1.5003.10.13.2.51.3.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7TxMTP3MSUVal | 1.3.6.1.4.1.5003.10.13.2.51.3.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7TxMTP3OctetsEntry | 1.3.6.1.4.1.5003.10.13.2.51.1.1 | not-accessible | ||
| U32 acPMSS7TxMTP3OctetsInterval | 1.3.6.1.4.1.5003.10.13.2.51.1.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7TxMTP3OctetsSN | 1.3.6.1.4.1.5003.10.13.2.51.1.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7TxMTP3OctetsTable | 1.3.6.1.4.1.5003.10.13.2.51.1 | not-accessible | Number of transmitted MTP3 octets per SS7 MTP3 node | |
| I32 acPMSS7TxMTP3OctetsTotal | 1.3.6.1.4.1.5003.10.13.2.51.1.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7TxMTP3OctetsVal | 1.3.6.1.4.1.5003.10.13.2.51.1.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7TxMTP3UPUEntry | 1.3.6.1.4.1.5003.10.13.2.51.5.1 | not-accessible | ||
| U32 acPMSS7TxMTP3UPUInterval | 1.3.6.1.4.1.5003.10.13.2.51.5.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7TxMTP3UPUSN | 1.3.6.1.4.1.5003.10.13.2.51.5.1.1 | Unsigned32 | not-accessible | SN number. 0 is the first SN. |
| acPMSS7TxMTP3UPUTable | 1.3.6.1.4.1.5003.10.13.2.51.5 | not-accessible | Number of transmitted MTP3 User Part Unavailable messages per SS7 MTP3 node | |
| I32 acPMSS7TxMTP3UPUTotal | 1.3.6.1.4.1.5003.10.13.2.51.5.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7TxMTP3UPUVal | 1.3.6.1.4.1.5003.10.13.2.51.5.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7TxOctetsEntry | 1.3.6.1.4.1.5003.10.13.2.31.9.1 | not-accessible | ||
| U32 acPMSS7TxOctetsInterval | 1.3.6.1.4.1.5003.10.13.2.31.9.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7TxOctetsLink | 1.3.6.1.4.1.5003.10.13.2.31.9.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7TxOctetsTable | 1.3.6.1.4.1.5003.10.13.2.31.9 | not-accessible | Number of transmitted Octets per SS7 link - Q.752 3.1 | |
| I32 acPMSS7TxOctetsTotal | 1.3.6.1.4.1.5003.10.13.2.31.9.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7TxOctetsVal | 1.3.6.1.4.1.5003.10.13.2.31.9.1.3 | Counter32 | read-only | Value of gauge or counter. |
| acPMSS7TxSignalUnitsEntry | 1.3.6.1.4.1.5003.10.13.2.31.7.1 | not-accessible | ||
| U32 acPMSS7TxSignalUnitsInterval | 1.3.6.1.4.1.5003.10.13.2.31.7.1.2 | Unsigned32 | not-accessible | Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
| U32 acPMSS7TxSignalUnitsLink | 1.3.6.1.4.1.5003.10.13.2.31.7.1.1 | Unsigned32 | not-accessible | Link number. 0 is the first link. |
| acPMSS7TxSignalUnitsTable | 1.3.6.1.4.1.5003.10.13.2.31.7 | not-accessible | Number of transmitted Signaling units per SS7 link | |
| I32 acPMSS7TxSignalUnitsTotal | 1.3.6.1.4.1.5003.10.13.2.31.7.1.4 | Integer32 | read-only | Total since last reset. |
| C32 acPMSS7TxSignalUnitsVal | 1.3.6.1.4.1.5003.10.13.2.31.7.1.3 | Counter32 | read-only | Value of gauge or counter. |
RFC description
Monitors performance metrics for SS7 signaling protocol elements in AudioCodes telephony devices.
Start monitoring AudioCodes gateways (SS7 signaling) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.