A3COM-HUAWEI-RRPP-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › A3COM-HUAWEI-RRPP-MIB

Organization: Huawei 3Com Technologies Co., Ltd.

Last Updated: 2004-12-02

Category: Routing Protocols, Vendor: H3C/HH3C

Description: Handles the H3C/3Com Rapid Ring Protection Protocol (RRPP), a vendor-proprietary protocol delivering fast recovery for ring-topology Ethernet LAN redundancy.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is A3COM-HUAWEI-RRPP-MIB?

A3COM-HUAWEI-RRPP-MIB is a joint 3Com/H3C (Huawei-3Com) vendor MIB managing the Rapid Ring Protection Protocol (RRPP), a proprietary alternative to Spanning Tree that provides sub-second failover for Ethernet switches wired in a ring topology. It exposes ring-domain configuration (domain ID, control VLAN, hello/fail timers, protected VLAN instance lists), global RRPP enable state and authentication password settings, and per-ring status/notification objects. Its monitoring value is chiefly software/protocol status and fault detection: h3cRrppEnableStatus and per-domain h3cRrppDomainHelloTime/h3cRrppDomainFailTime reveal whether ring protection is active and correctly timed, while h3cRrppNotifications alert on ring breaks or topology changes that RRPP is recovering from. The module description explicitly frames RRPP as functionally comparable to Spanning Tree Protocol, indicating a conceptual (though not structural) relationship to the IETF Bridge/STP MIBs. It is deployed on H3C/3Com/Huawei enterprise and campus switches wired in Ethernet ring topologies for fast link-failure recovery. Engineers can download the A3COM-HUAWEI-RRPP-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in A3COM-HUAWEI-RRPP-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • H3C/3Com/Huawei-3Com Ethernet switch (ring topology)

Monitoring Examples

An operator would poll h3cRrppEnableStatus and h3cRrppDomainTable/h3cRrppDomainEntry rows keyed by h3cRrppDomainID to confirm ring protection is enabled and that h3cRrppDomainControlVlanID matches the intended control VLAN. Checking h3cRrppDomainHelloTime against h3cRrppDomainFailTime would reveal a timer misconfiguration that could delay failover detection. Subscribing to h3cRrppNotifications would alert the NMS when a ring link break or master-node role change occurs, and h3cRrppDomainRowStatus would confirm whether a given ring domain's configuration row is active.

What Can Be Monitored

  • RRPP enable status
  • ring domain configuration (control VLAN, hello/fail timers)
  • protected VLAN instance list
  • ring break / topology change notifications
  • domain row status
Imported Objects

From A3COM-HUAWEI-OID-MIB

h3cCommonOBJECT-IDENTITY

From SNMPv2-SMI

Counter32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

RowStatus
TEXTUAL-CONVENTION

How to Use in IPNetwork Monitor

Example using h3cRrppPortRXError OID:

Select an H3C/3Com Ethernet ring switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type h3cRrppPortRXError into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The statistics of illegal RRPP packets received from this port. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Manages the H3C/3Com Rapid Ring Protection Protocol (RRPP), a proprietary fast-recovery ring topology protocol for Ethernet LAN redundancy.

Start monitoring H3C/3Com Ethernet ring switches with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download A3COM-HUAWEI-RRPP-MIB