ZYXEL-IESCOMMON-MIB :: iesSlotModuleAlarmStatus

MIB Reference — IPNetwork Monitor

All MIBsZYXEL-IESCOMMON-MIBiesSlotModuleAlarmStatus

iesSlotModuleAlarmStatus

Module: ZYXEL-IESCOMMON-MIB

OID (symbolic): ZYXEL-IESCOMMON-MIB::iesSlotModuleAlarmStatus

OID (numeric): 1.3.6.1.4.1.890.1.5.13.1.1.3.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description:

This variable indicates the alarm status of the module. It is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The moduleNoDefect should be set if and only if no other flag is set.

The various bit positions are: 1 moduleNoDefect 2 moduleOverHeat 3 moduleFanRpmLow 4 moduleVoltageLow 5 moduleThermalSensorFailure 6 modulePullOut 7 powerDC48VAFailure 8 powerDC48VBFailure 9 extAlarmInputTrigger 10 moduleDown 11 mscSwitchOverOK 12 networkTopologyChange

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.890.1.5.13.1.1.3.1.8
snmpwalk -v2c -c public <target> ZYXEL-IESCOMMON-MIB::iesSlotModuleAlarmStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.890.1.5.13.1.1.3.1.8.1
snmpget -v2c -c public <target> ZYXEL-IESCOMMON-MIB::iesSlotModuleAlarmStatus.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.890zyxelZYXEL-accessSwitch-MIB
1.3.6.1.4.1.890.1productsZYXEL-accessSwitch-MIB
1.3.6.1.4.1.890.1.5accessSwitchZYXEL-accessSwitch-MIB
1.3.6.1.4.1.890.1.5.13.1.1iesChassisZYXEL-IESCOMMON-MIB
1.3.6.1.4.1.890.1.5.13.1.1.3iesSlotTableZYXEL-IESCOMMON-MIB
1.3.6.1.4.1.890.1.5.13.1.1.3.1iesSlotEntryZYXEL-IESCOMMON-MIB
1.3.6.1.4.1.890.1.5.13.1.1.3.1.8iesSlotModuleAlarmStatusZYXEL-IESCOMMON-MIB