ZTE-AN-OTDR-MIB :: zxAnOtdrCtrlCardCurrentTemp

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ZTE-AN-OTDR-MIB › zxAnOtdrCtrlCardCurrentTemp

zxAnOtdrCtrlCardCurrentTemp

Module: ZTE-AN-OTDR-MIB

OID (symbolic): ZTE-AN-OTDR-MIB::zxAnOtdrCtrlCardCurrentTemp

OID (numeric): 1.3.6.1.4.1.3902.1083.5.1.2.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The current control card temperature of OTDR equipment.

What is zxAnOtdrCtrlCardCurrentTemp?

Reports the current temperature of the OTDR control card in degrees Celsius. Admins monitor this alongside zxAnOtdrCtrlCardTempHighThresh and zxAnOtdrCtrlCardTempLowThresh to catch overheating or cold-start conditions before they trigger a temperature alarm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3902.1083.5.1.2.1.1
snmpwalk -v2c -c public <target> ZTE-AN-OTDR-MIB::zxAnOtdrCtrlCardCurrentTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3902.1083.5.1.2.1.1.1
snmpget -v2c -c public <target> ZTE-AN-OTDR-MIB::zxAnOtdrCtrlCardCurrentTemp.1

Start monitoring ZTE Access Node (PON/fiber interfaces with integrated OTDR) (fiber-fault-distance/loss test-result status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZTE-AN-OTDR-MIB::zxAnOtdrCtrlCardCurrentTemp OID value, configure state conditions and alerts, and monitor any ZTE Access Node (PON/fiber interfaces with integrated OTDR) (fiber-fault-distance/loss test-result status) from a single console.

How to Use in IPNetwork Monitor

Select a ZTE Access Node (PON/fiber interfaces with integrated OTDR) (fiber-fault-distance/loss test-result status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type zxAnOtdrCtrlCardCurrentTemp into the Find box to locate it in the OID tree, then select it and click OK. The current control card temperature of OTDR equipment. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3902zteDPI-MIB
1.3.6.1.4.1.3902.1083zxAnOfdZTE-AN-OFD-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3902.1083.5zxAnOtdrMibZTE-AN-OTDR-MIB
1.3.6.1.4.1.3902.1083.5.1zxAnOtdrGlobalObjectsZTE-AN-OTDR-MIB
1.3.6.1.4.1.3902.1083.5.1.2zxAnOtdrEnvGlobalObjectsZTE-AN-OTDR-MIB
1.3.6.1.4.1.3902.1083.5.1.2.1zxAnOtdrEnvCtrlCardGlobalObjectsZTE-AN-OTDR-MIB
1.3.6.1.4.1.3902.1083.5.1.2.1.1zxAnOtdrCtrlCardCurrentTempZTE-AN-OTDR-MIB