ZMTEL-ODU-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ZMTEL-ODU-MIB

Organization: Zmtel Co. Ltd.

Last Updated: 2015-08-03

Description: Zmtel enterprise MIB for LTE outdoor units (ODU), exposing device identity, system, LTE radio, WAN, and LAN information on Zmtel ODU hardware

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ZMTEL-ODU-MIB?

This is a Zmtel enterprise MIB for the company's LTE Outdoor Unit (ODU) product line, a fixed-wireless LTE customer-premises radio device typically mounted outdoors to provide cellular backhaul or last-mile broadband access. It exposes device identity information (vendor, product/model name, hardware and software/firmware versions, serial numbers, IMEI/IMSI), along with LTE radio parameters, WAN connectivity information, and LAN-side configuration. Its monitoring value is strongly hardware/software-status oriented: administrators use it to confirm the exact hardware and firmware/bootROM version running on the unit, verify the SIM/module identity via IMEI/IMSI, and check LTE radio and WAN link status to diagnose connectivity issues on the cellular link. It has no apparent dependency on external standards MIBs, functioning as a self-contained Zmtel proprietary identity/status model, though it would logically sit alongside standard IF-MIB objects for the unit's LAN interface. It is deployed on Zmtel outdoor LTE CPE units providing fixed-wireless broadband access in areas served by cellular backhaul rather than fixed-line infrastructure. Network engineers evaluating or troubleshooting this functionality can download the ZMTEL-ODU-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in ZMTEL-ODU-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Zmtel LTE Outdoor Unit (ODU) fixed-wireless CPE

Monitoring Examples

An administrator would poll deviceInfo/systemInfo objects such as modelName, hardwareVersion, softwareVersion, and firmwareVersion to confirm which firmware build is running on a given ODU before or after a remote upgrade, and check SN, moduleSN, IMEI, and IMSI to verify the correct SIM/module is installed in the field unit. Polling lteInfo objects like lteBand alongside general LTE radio status would reveal whether the unit is camped on the expected LTE band or has fallen back to a weaker signal band due to poor cellular coverage.

What Can Be Monitored

  • hardware/software/firmware version
  • serial number and module serial number
  • IMEI/IMSI identity
  • LTE band and radio status
  • WAN and LAN connection info
Imported Objects

From RFC1155-SMI

IpAddress
NetworkAddress

From SNMPv2-SMI

Counter64
Gauge32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-IDENTITY
OBJECT-TYPE
TimeTicks
Unsigned32
enterprises

From SNMPv2-TC

DisplayString

How to Use in IPNetwork Monitor

Example using dlDataRateCurrent OID:

Select a Zmtel LTE Outdoor Unit (ODU) fixed-wireless CPE (hardware/firmware-version, LTE-radio/WAN-link status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dlDataRateCurrent into the Find box to locate it in the OID tree, then select it and click OK. Indicates the mobile network downlink current data rate(Bytes/s). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

MIB for Zmtel LTE ODU (Outdoor Unit) devices defining device information, system status, and network interface monitoring.

Start monitoring Zmtel LTE Outdoor Unit (ODU) fixed-wireless CPE (hardware/firmware-version, LTE-radio/WAN-link status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download ZMTEL-ODU-MIB