All MIBs › ZHONE-SYSTEM-MIB › zhoneSystemOutletTemperatureHighThreshold
zhoneSystemOutletTemperatureHighThreshold
Module: ZHONE-SYSTEM-MIB
OID (symbolic): ZHONE-SYSTEM-MIB::zhoneSystemOutletTemperatureHighThreshold
OID (numeric): 1.3.6.1.4.1.5504.3.1.5.26
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description:
Specifies the outlet sensor high temperature threshold. Minor, Major & Critical alarms will be raised when outlet sensor temperature reaches X, X+5 & X+10 respectively. X is the value of this field. Allowed range for MXK & MX1U products is 35 to 65 Allowed range for MX1U160Lt is 35 to 75
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5504.3.1.5.26 snmpwalk -v2c -c public <target> ZHONE-SYSTEM-MIB::zhoneSystemOutletTemperatureHighThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5504.3.1.5.26.1 snmpget -v2c -c public <target> ZHONE-SYSTEM-MIB::zhoneSystemOutletTemperatureHighThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5504.3.1.5.26.1 i <value>