ZHNHPNA :: hpnaStationRxPower

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ZHNHPNA › hpnaStationRxPower

hpnaStationRxPower

Module: ZHNHPNA

OID (symbolic): ZHNHPNA::hpnaStationRxPower

OID (numeric): 1.3.6.1.4.1.5504.2.5.47.1.3.1.7

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: HPNA receive power, in dBm.

What is hpnaStationRxPower?

This reports the received signal power, in dBm, measured for this HPNA station's incoming signal. Admins use it to assess phoneline signal quality — a weak or excessively attenuated signal often explains poor throughput or intermittent connectivity on that link. For example, a reading of -45 dBm might be flagged as marginal compared to a healthy link's -20 dBm, prompting a check of the phone wiring or splitters.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5504.2.5.47.1.3.1.7
snmpwalk -v2c -c public <target> ZHNHPNA::hpnaStationRxPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5504.2.5.47.1.3.1.7.1
snmpget -v2c -c public <target> ZHNHPNA::hpnaStationRxPower.1

Start monitoring Zhone Technologies CPE equipment, HPNA/HCNA in-home networking (link-rate/RX-power status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZHNHPNA::hpnaStationRxPower OID value, configure state conditions and alerts, and monitor any Zhone Technologies CPE equipment, HPNA/HCNA in-home networking (link-rate/RX-power status) from a single console.

How to Use in IPNetwork Monitor

Select a Zhone Technologies CPE equipment, HPNA/HCNA in-home networking (link-rate/RX-power status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpnaStationRxPower into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports hPNA receive power, in dBm. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reading drifts outside the range expected for a healthy link, since a sustained power drop often precedes a fiber/cable fault or connector issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5504ZhoneBITSTORM-HP-160-MIB
1.3.6.1.4.1.5504.2zhoneProductZhone
1.3.6.1.4.1.5504.2.5zhoneWtnZhone
Numeric OIDNameModule
1.3.6.1.4.1.5504.2.5.47zhnHpnaZHNHPNA
1.3.6.1.4.1.5504.2.5.47.1zhnHpnaObjectsZHNHPNA
1.3.6.1.4.1.5504.2.5.47.1.3hpnaStationsTableZHNHPNA
1.3.6.1.4.1.5504.2.5.47.1.3.1hpnaStationsEntryZHNHPNA
1.3.6.1.4.1.5504.2.5.47.1.3.1.7hpnaStationRxPowerZHNHPNA