XPPC-MIB :: upsSmartInputLineFailCause

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsXPPC-MIBupsSmartInputLineFailCause

upsSmartInputLineFailCause

Module: XPPC-MIB

OID (symbolic): XPPC-MIB::upsSmartInputLineFailCause

OID (numeric): 1.3.6.1.4.1.935.1.1.1.3.2.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and ground.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.935.1.1.1.3.2.5
snmpwalk -v2c -c public <target> XPPC-MIB::upsSmartInputLineFailCause

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.935.1.1.1.3.2.5.1
snmpget -v2c -c public <target> XPPC-MIB::upsSmartInputLineFailCause.1

Start monitoring Vendor UPS/power-management appliance, PPC product line (trap-receiver config, UPS model/firmware status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the XPPC-MIB::upsSmartInputLineFailCause OID value, configure state conditions and alerts, and monitor any Vendor UPS/power-management appliance, PPC product line (trap-receiver config, UPS model/firmware status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.935ppcTELECOM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.935.1productsXPPC-MIB
1.3.6.1.4.1.935.1.1hardwareXPPC-MIB
1.3.6.1.4.1.935.1.1.1upsXPPC-MIB
1.3.6.1.4.1.935.1.1.1.3upsInputpXPPC-MIB
1.3.6.1.4.1.935.1.1.1.3.2upsSmartInputXPPC-MIB
1.3.6.1.4.1.935.1.1.1.3.2.5upsSmartInputLineFailCauseXPPC-MIB