All MIBs › Wellfleet-SYNC-MIB › wfSyncForceIFTF
wfSyncForceIFTF
Module: Wellfleet-SYNC-MIB
OID (symbolic): Wellfleet-SYNC-MIB::wfSyncForceIFTF
OID (numeric): 1.3.6.1.4.1.18.3.4.5.1.96
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Specifies the Inter Frame Time Fill (IFTF) pattern which gets transmitted when no data is being transmitted on a particular channel. For SDLC Lines, DEFAULT and FORCE_HDLC_FLAGS both result in HDLC Flags (0x7E) as the fill character. FLAGSTREAMING will cause the fill character to alternate between Flags (0x7E) and Idles (0xFF), depending upon the current state of the line. For ISDN BRI Lines, DEFAULT, FORCE IDLES and FLAGSTREAMING all result in Idles (0xFF) as the fill character.
For all other line types, DEFAULT, FORCE HDLC FLAGS and FLAGSTREAMING all result in HDLC Flags (0x7E) as the fill character.
Leave this field at the default unless required for the attached device. The AS/400 high speed serial controller requires the use of FLAGSTREAMING for error-free operation.
What is wfSyncForceIFTF?
Controls the Inter-Frame Time Fill pattern sent between frames when the channel is otherwise idle: default(1)/forcehdlcflags(2) usually send HDLC flags (0x7E), forceidles(3) sends idle bytes (0xFF, the norm on ISDN BRI), and flagstreaming(4) alternates flags and idles; the DESCRIPTION notes AS/400 high-speed serial controllers specifically require flagstreaming for error-free operation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.4.5.1.96 snmpwalk -v2c -c public <target> Wellfleet-SYNC-MIB::wfSyncForceIFTF
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.4.5.1.96.1 snmpget -v2c -c public <target> Wellfleet-SYNC-MIB::wfSyncForceIFTF.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.4.5.1.96.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> wfSyncForceIFTF.1
Start monitoring Wellfleet router, Bay Networks router with synchronous serial WAN interface (clock-source/sync error-counter status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-SYNC-MIB::wfSyncForceIFTF OID value, configure state conditions and alerts, and monitor any Wellfleet router, Bay Networks router with synchronous serial WAN interface (clock-source/sync error-counter status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.4 | wfLine | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.4.5 | wfSyncTable | Wellfleet-SYNC-MIB |
| 1.3.6.1.4.1.18.3.4.5.1 | wfSyncEntry | Wellfleet-SYNC-MIB |
| 1.3.6.1.4.1.18.3.4.5.1.96 | wfSyncForceIFTF | Wellfleet-SYNC-MIB |