All MIBs › Wellfleet-SMDS-MIB › wfSmdsCircuitHrtbtPollDownCount
wfSmdsCircuitHrtbtPollDownCount
Module: Wellfleet-SMDS-MIB
OID (symbolic): Wellfleet-SMDS-MIB::wfSmdsCircuitHrtbtPollDownCount
OID (numeric): 1.3.6.1.4.1.18.3.5.9.3.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: if this many consecutive heartbeat polling messages go unacknowledged, log an event declaring the line down
What is wfSmdsCircuitHrtbtPollDownCount?
This read-write integer, from 1 to 2147483647 with a default of 3, sets how many consecutive unacknowledged heartbeat polls trigger a logged line-down event. Admins tune this to control how tolerant the circuit is of transient polling misses before declaring the line down. For example, raising this from the default 3 to 5 would make the router wait for five consecutive missed heartbeats before logging the line as down, reducing false alarms on a marginal but still-working link.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.3.1.10 snmpwalk -v2c -c public <target> Wellfleet-SMDS-MIB::wfSmdsCircuitHrtbtPollDownCount
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.3.1.10.1 snmpget -v2c -c public <target> Wellfleet-SMDS-MIB::wfSmdsCircuitHrtbtPollDownCount.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.9.3.1.10.1 i <value>
Start monitoring Wellfleet/Bay Networks/Nortel routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-SMDS-MIB::wfSmdsCircuitHrtbtPollDownCount OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks/Nortel routers from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5 | wfApplication | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.9 | wfWanGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.5.9.3 | wfSmdsCircuitTable | Wellfleet-SMDS-MIB |
| 1.3.6.1.4.1.18.3.5.9.3.1 | wfSmdsCircuitEntry | Wellfleet-SMDS-MIB |
| 1.3.6.1.4.1.18.3.5.9.3.1.10 | wfSmdsCircuitHrtbtPollDownCount | Wellfleet-SMDS-MIB |