Wellfleet-OSPF-MIB :: wfMospfEntryTimeoutValue

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-OSPF-MIB › wfMospfEntryTimeoutValue

wfMospfEntryTimeoutValue

Module: Wellfleet-OSPF-MIB

OID (symbolic): Wellfleet-OSPF-MIB::wfMospfEntryTimeoutValue

OID (numeric): 1.3.6.1.4.1.18.3.5.3.2.3.1.26

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The timer value for timing out MOSPF forward entries.

What is wfMospfEntryTimeoutValue?

Sets, in seconds, how long an idle MOSPF multicast forwarding entry is kept before being aged out and removed, defaulting to 600 seconds (10 minutes). Admins might lower this to reclaim forwarding-table resources faster on routers handling many short-lived multicast sessions, or raise it to avoid re-signaling for intermittent flows.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.3.2.3.1.26
snmpwalk -v2c -c public <target> Wellfleet-OSPF-MIB::wfMospfEntryTimeoutValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.3.2.3.1.26.1
snmpget -v2c -c public <target> Wellfleet-OSPF-MIB::wfMospfEntryTimeoutValue.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.3.2.3.1.26.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> wfMospfEntryTimeoutValue.1

Start monitoring Wellfleet/Bay Networks routers (OSPF neighbor-adjacency/LSA-database status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-OSPF-MIB::wfMospfEntryTimeoutValue OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks routers (OSPF neighbor-adjacency/LSA-database status) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5wfApplicationWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3wfInternetWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2wfIpRoutingWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2.3wfOspfGroupWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.3.2.3.1wfOspfGeneralGroupRFC7777-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.5.3.2.3.1.26wfMospfEntryTimeoutValueWellfleet-OSPF-MIB