Access: read-write

Description: This attribute has no affect on the Hardware configuration. This attribute is purely for any Network Management Tool to determine whether it configured the OC12 as Fractional or Clear.

What is wfOc12ConfigManagerMethod?

This read-write value, per its own description, has no effect on the actual hardware configuration and exists purely so a network management tool can record whether it configured this OC12 port as fractional, frac(1) the default, or clear(2). Admins (or more precisely, the management software they use) set it purely as a bookkeeping flag reflecting how the port was intended to be provisioned, without it actually changing the port's behavior. For example, a management tool that provisioned this OC12 port for clear-channel (unchannelized) operation would set this object to clear(2) purely as a record of that intent, since the object itself doesn't drive the hardware.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.4.24.20.1.12
snmpwalk -v2c -c public <target> Wellfleet-OC12-MIB::wfOc12ConfigManagerMethod

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.4.24.20.1.12.1
snmpget -v2c -c public <target> Wellfleet-OC12-MIB::wfOc12ConfigManagerMethod.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.4.24.20.1.12.1 i <value>

Start monitoring Wellfleet router, Bay Networks router with OC-12 SONET interface (section/line/path overhead alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-OC12-MIB::wfOc12ConfigManagerMethod OID value, configure state conditions and alerts, and monitor any Wellfleet router, Bay Networks router with OC-12 SONET interface (section/line/path overhead alarm status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.4wfLineWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.4.24wfSonetGroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.4.24.20wfOc12ConfigTableWellfleet-OC12-MIB
1.3.6.1.4.1.18.3.4.24.20.1wfOc12ConfigEntryWellfleet-OC12-MIB
1.3.6.1.4.1.18.3.4.24.20.1.12wfOc12ConfigManagerMethodWellfleet-OC12-MIB