All MIBs › Wellfleet-OC12-MIB › wfOc12ConfigLineStatus
wfOc12ConfigLineStatus
Module: Wellfleet-OC12-MIB
OID (symbolic): Wellfleet-OC12-MIB::wfOc12ConfigLineStatus
OID (numeric): 1.3.6.1.4.1.18.3.4.24.20.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: the status of the OC12
What is wfOc12ConfigLineStatus?
This read-only bitmask reports SONET line-level alarm conditions on the OC12 port: noalarm(1) the default, los(2) loss of signal, lof(4) loss of frame, ais(8) alarm indication signal, rdi(16) remote defect indication, loopback(128), or otherfailure(512). Admins check it for a more granular, potentially multi-condition view of line alarms than the single-value wfOc12ConfigState object provides. For example, a value combining the los and ais bits would tell an admin the port is both losing its own signal and receiving an alarm indication signal from the far end, consistent with a broken fiber link.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.4.24.20.1.6 snmpwalk -v2c -c public <target> Wellfleet-OC12-MIB::wfOc12ConfigLineStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.4.24.20.1.6.1 snmpget -v2c -c public <target> Wellfleet-OC12-MIB::wfOc12ConfigLineStatus.1
Start monitoring Wellfleet router, Bay Networks router with OC-12 SONET interface (section/line/path overhead alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-OC12-MIB::wfOc12ConfigLineStatus OID value, configure state conditions and alerts, and monitor any Wellfleet router, Bay Networks router with OC-12 SONET interface (section/line/path overhead alarm status) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.4 | wfLine | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.4.24 | wfSonetGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.4.24.20 | wfOc12ConfigTable | Wellfleet-OC12-MIB |
| 1.3.6.1.4.1.18.3.4.24.20.1 | wfOc12ConfigEntry | Wellfleet-OC12-MIB |
| 1.3.6.1.4.1.18.3.4.24.20.1.6 | wfOc12ConfigLineStatus | Wellfleet-OC12-MIB |