All MIBs › Wellfleet-IREDUND-MIB › wfIRedundIfPrimary
wfIRedundIfPrimary
Module: Wellfleet-IREDUND-MIB
OID (symbolic): Wellfleet-IREDUND-MIB::wfIRedundIfPrimary
OID (numeric): 1.3.6.1.4.1.18.3.5.1.10.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Primary flag, indicates if this has been chosen as the primary interface. Only one interface in any circuit can be selected as a PRIMARY interface. The PRIMARY interface will have priority when an active interface is selected for a circuit. In general, if a PRIMARY circuit is available at active interface selection time, it will be chosen as the active interface.
What is wfIRedundIfPrimary?
This read-write INTEGER, primary(1) or nonprimary(2), flags whether this interface has been chosen as the preferred (primary) member of its redundancy circuit. Only one interface per circuit can be marked primary, and it gets priority over other standby interfaces when the system selects which interface becomes active. An admin who wants a specific fiber uplink to be preferred over a backup copper link would set wfIRedundIfPrimary to primary(1) on that fiber interface's row.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.10.1.1.6 snmpwalk -v2c -c public <target> Wellfleet-IREDUND-MIB::wfIRedundIfPrimary
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.10.1.1.6.1 snmpget -v2c -c public <target> Wellfleet-IREDUND-MIB::wfIRedundIfPrimary.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.1.10.1.1.6.1 i <value>
Start monitoring Wellfleet Communications (Bay Networks) routers (interface-redundancy active/standby-failover status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-IREDUND-MIB::wfIRedundIfPrimary OID value, configure state conditions and alerts, and monitor any Wellfleet Communications (Bay Networks) routers (interface-redundancy active/standby-failover status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5 | wfApplication | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1 | wfDataLink | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1.10 | wfIRedundGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.5.1.10.1 | wfIRedundIfTable | Wellfleet-IREDUND-MIB |
| 1.3.6.1.4.1.18.3.5.1.10.1.1 | wfIRedundIfEntry | Wellfleet-IREDUND-MIB |
| 1.3.6.1.4.1.18.3.5.1.10.1.1.6 | wfIRedundIfPrimary | Wellfleet-IREDUND-MIB |