Wellfleet-IREDUND-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:44:24 EDT 1995 IMPORTS OBJECT-TYPE FROM RFC-1212 wfIRedundGroup FROM Wellfleet-COMMON-MIB; wfIRedundIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WfIRedundIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "WF_IREDUND_INTERFACE_TABLE - Interface REDUNDANCY This tabulates the interfaces within an interface redundancy group. All interfaces are indexed according to their physical slot and connector designation. All interfaces in the same circuit act as redundant (hot stand-by) interfaces for that circuit. At any given time, one hot stand-by interface is chosen to be the active interface for a circuit. The active interface is the only interface that is reading and writing data to/from the media." ::= { wfIRedundGroup 1 } wfIRedundIfEntry OBJECT-TYPE SYNTAX WfIRedundIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Redundant interface entries." INDEX { wfIRedundIfSlot, wfIRedundIfPort } ::= { wfIRedundIfTable 1 } WfIRedundIfEntry ::= SEQUENCE { wfIRedundIfDelete INTEGER, wfIRedundIfDisable INTEGER, wfIRedundIfCct INTEGER, wfIRedundIfSlot INTEGER, wfIRedundIfPort INTEGER, wfIRedundIfPrimary INTEGER, wfIRedundIfActive INTEGER, wfIRedundIfMACAddr OCTET STRING } wfIRedundIfDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Creation and deletion flag for this record. When set, it will cause this entry to be deleted from the MIB." DEFVAL { created } ::= { wfIRedundIfEntry 1 } wfIRedundIfDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable parameter. A disabled interface will never be selected as the active interface for a circuit." DEFVAL { enabled } ::= { wfIRedundIfEntry 2 } wfIRedundIfCct OBJECT-TYPE SYNTAX INTEGER(1..1023) ACCESS read-write STATUS mandatory DESCRIPTION "The circuit number of the circuit to which the interface belongs. This interface will either act as the active interface for the the circuit or as a hot stand-by." ::= { wfIRedundIfEntry 3 } wfIRedundIfSlot OBJECT-TYPE SYNTAX INTEGER(1..14) ACCESS read-only STATUS mandatory DESCRIPTION "Slot ID of the interface, used as instance ID" ::= { wfIRedundIfEntry 4 } wfIRedundIfPort OBJECT-TYPE SYNTAX INTEGER(1..44) ACCESS read-only STATUS mandatory DESCRIPTION "Port ID of the interface, used as instance ID" ::= { wfIRedundIfEntry 5 } wfIRedundIfPrimary OBJECT-TYPE SYNTAX INTEGER { primary(1), nonprimary(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Primary flag, indicates if this has been chosen as the primary interface. Only one interface in any circuit can be selected as a PRIMARY interface. The PRIMARY interface will have priority when an active interface is selected for a circuit. In general, if a PRIMARY circuit is available at active interface selection time, it will be chosen as the active interface." DEFVAL { nonprimary } ::= { wfIRedundIfEntry 6 } wfIRedundIfActive OBJECT-TYPE SYNTAX INTEGER { notavailable(1), standby(2), active(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Active flag, indicates if this interface is the current active interface for the Interface Redundancy Group, or a standby interface, or not available to be used as active interface." DEFVAL { notavailable } ::= { wfIRedundIfEntry 7 } wfIRedundIfMACAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "MAC Address being used by Interface Redundancy as Primary MAC Address." ::= { wfIRedundIfEntry 8 } END -- Wellfleet-IREDUND-MIB