Wellfleet-IREDUND-MIB :: wfIRedundIfMACAddr

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-IREDUND-MIB › wfIRedundIfMACAddr

wfIRedundIfMACAddr

Module: Wellfleet-IREDUND-MIB

OID (symbolic): Wellfleet-IREDUND-MIB::wfIRedundIfMACAddr

OID (numeric): 1.3.6.1.4.1.18.3.5.1.10.1.1.8

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: MAC Address being used by Interface Redundancy as Primary MAC Address.

What is wfIRedundIfMACAddr?

This read-only OCTET STRING is the MAC address that Interface Redundancy uses as the shared Primary MAC Address for the circuit. It lets an admin verify which single MAC address downstream devices will see regardless of which physical interface in the redundancy group is currently active, which is what makes failover transparent at layer 2. If a downstream switch's ARP table shows a MAC address that doesn't match this OID's value, that would indicate the redundancy configuration isn't behaving as expected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.10.1.1.8
snmpwalk -v2c -c public <target> Wellfleet-IREDUND-MIB::wfIRedundIfMACAddr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.10.1.1.8.1
snmpget -v2c -c public <target> Wellfleet-IREDUND-MIB::wfIRedundIfMACAddr.1

Start monitoring Wellfleet Communications (Bay Networks) routers (interface-redundancy active/standby-failover status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-IREDUND-MIB::wfIRedundIfMACAddr OID value, configure state conditions and alerts, and monitor any Wellfleet Communications (Bay Networks) routers (interface-redundancy active/standby-failover status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5wfApplicationWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.1wfDataLinkWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.1.10wfIRedundGroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.5.1.10.1wfIRedundIfTableWellfleet-IREDUND-MIB
1.3.6.1.4.1.18.3.5.1.10.1.1wfIRedundIfEntryWellfleet-IREDUND-MIB
1.3.6.1.4.1.18.3.5.1.10.1.1.8wfIRedundIfMACAddrWellfleet-IREDUND-MIB