All MIBs › Wellfleet-FDDI-MIB › wfFddiSmtStationAction
wfFddiSmtStationAction
Module: Wellfleet-FDDI-MIB
OID (symbolic): Wellfleet-FDDI-MIB::wfFddiSmtStationAction
OID (numeric): 1.3.6.1.4.1.18.3.4.15.1.4.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This object when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows:
Other: Results in a BadValue error
Connect: Generates a connect signal to ECM to begin a connection sequence. The 'wfFddiSmtRemoteDisconnectFlag' is cleared on the setting of this variable to 1.
Disconnect: Generates a disconnect signal to ECM and sets the 'wfFddiSmtRemoteDisconnectFlag' to TRUE.
Path_Test: Initiates a station path test. The 'PathTest' variable is set to 'Testing'. The results of this action are not specified in the standard.
Self_test: Initiates a station self test. The results of this action are not specified in the standard. Disable_A: Disable_A causes a PC_Disable on the A port if the A port mode is peer.
Disable_B: Disable_B causes a PC_Disable on the B port if the B port mode is peer.
Disable_M: Disable_M causes a PC_Disable on all M ports.
Attempts to set this object to all other values results in a BadValue error. Agents may elect to return a BadValue error on attempts to set this variable to PathTest or SelfTest.
What is wfFddiSmtStationAction?
Always reads back as other(1); writing to it triggers a one-shot station action: connect(2) signals ECM to begin connecting to the ring and clears wfFddiSmtRemoteDisconnectFlag, disconnect(3) signals ECM to disconnect and sets that flag, pathtest(4)/selftest(5) kick off diagnostic self-tests, and disablea(6)/disableb(7)/disablem(8) issue a PC_Disable on the station's A, B, or M ports respectively; writing other(1) or any unsupported value returns a BadValue error.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.4.15.1.4.1.5 snmpwalk -v2c -c public <target> Wellfleet-FDDI-MIB::wfFddiSmtStationAction
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.4.15.1.4.1.5.1 snmpget -v2c -c public <target> Wellfleet-FDDI-MIB::wfFddiSmtStationAction.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.4.15.1.4.1.5.1 i <value>
Start monitoring Wellfleet/Bay Networks routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-FDDI-MIB::wfFddiSmtStationAction OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks routers from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.4 | wfLine | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.4.15 | wfFddiGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.4.15.1 | wfFddiSmtGroup | Wellfleet-FDDI-MIB |
| 1.3.6.1.4.1.18.3.4.15.1.4 | wfFddiSmtActionTable | Wellfleet-FDDI-MIB |
| 1.3.6.1.4.1.18.3.4.15.1.4.1 | wfFddiSmtActionEntry | Wellfleet-FDDI-MIB |
| 1.3.6.1.4.1.18.3.4.15.1.4.1.5 | wfFddiSmtStationAction | Wellfleet-FDDI-MIB |