Wellfleet-FDDI-MIB :: wfFddiMacFrameErrorRatio

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-FDDI-MIB › wfFddiMacFrameErrorRatio

wfFddiMacFrameErrorRatio

Module: Wellfleet-FDDI-MIB

OID (symbolic): Wellfleet-FDDI-MIB::wfFddiMacFrameErrorRatio

OID (numeric): 1.3.6.1.4.1.18.3.4.15.2.3.1.15

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This variable is the value of the ratio:

((delta wfFddiMacLostCts + delta wfFddiMacErrorCts) / (delta wfFddiMacFrameCts + delta wfFddiMacLostCts)) 2**16)

What is wfFddiMacFrameErrorRatio?

Reports the calculated ratio of (delta wfFddiMacLostCts + delta wfFddiMacErrorCts) to (delta frame count + delta wfFddiMacLostCts), scaled by 2^16, which the station compares against wfFddiMacFrameErrorThreshold to decide whether to raise a MAC Frame Error Condition report.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.4.15.2.3.1.15
snmpwalk -v2c -c public <target> Wellfleet-FDDI-MIB::wfFddiMacFrameErrorRatio

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.4.15.2.3.1.15.1
snmpget -v2c -c public <target> Wellfleet-FDDI-MIB::wfFddiMacFrameErrorRatio.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> wfFddiMacFrameErrorRatio.1

Start monitoring Wellfleet/Bay Networks routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-FDDI-MIB::wfFddiMacFrameErrorRatio OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks routers from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.4wfLineWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.4.15wfFddiGroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.4.15.2wfFddiMacGroupWellfleet-FDDI-MIB
1.3.6.1.4.1.18.3.4.15.2.3wfFddiMacExtTableWellfleet-FDDI-MIB
1.3.6.1.4.1.18.3.4.15.2.3.1wfFddiMacExtEntryWellfleet-FDDI-MIB
1.3.6.1.4.1.18.3.4.15.2.3.1.15wfFddiMacFrameErrorRatioWellfleet-FDDI-MIB