All MIBs › Wellfleet-DSX3-MIB › wfDsx3ThrAlrtSEFSs
wfDsx3ThrAlrtSEFSs
Module: Wellfleet-DSX3-MIB
OID (symbolic): Wellfleet-DSX3-MIB::wfDsx3ThrAlrtSEFSs
OID (numeric): 1.3.6.1.4.1.18.3.4.26.18.1.5
Node type: OBJECT-TYPE
Type: Gauge
Access: read-write
Description: The number of Severely Errored Framing Seconds which must be received prior to the generation of a Threshold Crossing Alert.
What is wfDsx3ThrAlrtSEFSs?
This read-write Gauge sets how many Severely Errored Framing Seconds must accumulate in the near-end bucket before the device raises a Threshold Crossing Alert for the circuit; the factory default is 0. An admin lowers it to get earlier warning of DS3 line trouble (a value of 0 means the alert only fires once 0 severely errored framing seconds have been counted, since the DS3/E3 framer lost frame alignment).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.4.26.18.1.5 snmpwalk -v2c -c public <target> Wellfleet-DSX3-MIB::wfDsx3ThrAlrtSEFSs
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.4.26.18.1.5.1 snmpget -v2c -c public <target> Wellfleet-DSX3-MIB::wfDsx3ThrAlrtSEFSs.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.4.26.18.1.5.1 i <value>
Start monitoring Wellfleet/Bay Networks router with DS3/DSX-3 interfaces, legacy (cross-connect mapping/error-counter status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-DSX3-MIB::wfDsx3ThrAlrtSEFSs OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks router with DS3/DSX-3 interfaces, legacy (cross-connect mapping/error-counter status) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.4 | wfLine | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.4.26 | wfDsx3Group | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.4.26.18 | wfDsx3ThrAlrtTable | Wellfleet-DSX3-MIB |
| 1.3.6.1.4.1.18.3.4.26.18.1 | wfDsx3ThrAlrtEntry | Wellfleet-DSX3-MIB |
| 1.3.6.1.4.1.18.3.4.26.18.1.5 | wfDsx3ThrAlrtSEFSs | Wellfleet-DSX3-MIB |