All MIBs › Wellfleet-CCTOPTS-MIB › wfCctOptsNormalPriorityQueueLimit
wfCctOptsNormalPriorityQueueLimit
Module: Wellfleet-CCTOPTS-MIB
OID (symbolic): Wellfleet-CCTOPTS-MIB::wfCctOptsNormalPriorityQueueLimit
OID (numeric): 1.3.6.1.4.1.18.3.5.1.4.1.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Normal Priority Queue limit The minimum valid value is zero. no maximum valid value (limited by bufs for the slot)
What is wfCctOptsNormalPriorityQueueLimit?
Maximum number of packets the normal-priority queue on this circuit may hold before further packets are clipped. The named default is 20, the minimum is zero, and there is no fixed maximum (limited by the slot's buffers). Tune it upward if normal-priority traffic is being dropped during short bursts.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.5 snmpwalk -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsNormalPriorityQueueLimit
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.5.1 snmpget -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsNormalPriorityQueueLimit.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.5.1 i <value>
Start monitoring Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-CCTOPTS-MIB::wfCctOptsNormalPriorityQueueLimit OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5 | wfApplication | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1 | wfDataLink | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1.4 | wfCircuitOptsGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.5.1.4.1 | wfCctOptsTable | Wellfleet-CCTOPTS-MIB |
| 1.3.6.1.4.1.18.3.5.1.4.1.1 | wfCctOptsEntry | Wellfleet-CCTOPTS-MIB |
| 1.3.6.1.4.1.18.3.5.1.4.1.1.5 | wfCctOptsNormalPriorityQueueLimit | Wellfleet-CCTOPTS-MIB |