Module: Wellfleet-CCTOPTS-MIB
OID (symbolic): Wellfleet-CCTOPTS-MIB::wfCctOptsNormalPercent
OID (numeric): 1.3.6.1.4.1.18.3.5.1.4.1.1.26
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The minimum percent of the SYNC line that Normal-priority traffic will get (if there is any) when the Bandwidth Allocation feature is enabled. See text for wfCctOptsHiPercent for more information.
What is wfCctOptsNormalPercent?
Minimum percent of the synchronous line that normal-priority traffic gets (if any is waiting) when bandwidth allocation is enabled; the named default is 20. Together with the high and low percentages it guarantees normal traffic a share even when high-priority traffic is heavy.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.26 snmpwalk -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsNormalPercent
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.26.1 snmpget -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsNormalPercent.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.26.1 i <value>
Start monitoring Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-CCTOPTS-MIB::wfCctOptsNormalPercent OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5 | wfApplication | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1 | wfDataLink | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1.4 | wfCircuitOptsGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.5.1.4.1 | wfCctOptsTable | Wellfleet-CCTOPTS-MIB |
| 1.3.6.1.4.1.18.3.5.1.4.1.1 | wfCctOptsEntry | Wellfleet-CCTOPTS-MIB |
| 1.3.6.1.4.1.18.3.5.1.4.1.1.26 | wfCctOptsNormalPercent | Wellfleet-CCTOPTS-MIB |