All MIBs › Wellfleet-CCTOPTS-MIB › wfCctOptsLowPriorityQueueLimit
wfCctOptsLowPriorityQueueLimit
Module: Wellfleet-CCTOPTS-MIB
OID (symbolic): Wellfleet-CCTOPTS-MIB::wfCctOptsLowPriorityQueueLimit
OID (numeric): 1.3.6.1.4.1.18.3.5.1.4.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Low Priority Queue limit The minimum valid value is zero. no maximum valid value (limited by bufs for the slot)
What is wfCctOptsLowPriorityQueueLimit?
Maximum number of packets the low-priority queue on this circuit may hold before further packets are clipped. The named default is 20, the minimum is zero, and there is no fixed maximum (limited by the slot's buffers). A small value protects buffer memory but means bulk, low-priority traffic is dropped sooner when the link is congested.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.6 snmpwalk -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsLowPriorityQueueLimit
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.6.1 snmpget -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsLowPriorityQueueLimit.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.6.1 i <value>
Start monitoring Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-CCTOPTS-MIB::wfCctOptsLowPriorityQueueLimit OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5 | wfApplication | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1 | wfDataLink | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1.4 | wfCircuitOptsGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.5.1.4.1 | wfCctOptsTable | Wellfleet-CCTOPTS-MIB |
| 1.3.6.1.4.1.18.3.5.1.4.1.1 | wfCctOptsEntry | Wellfleet-CCTOPTS-MIB |
| 1.3.6.1.4.1.18.3.5.1.4.1.1.6 | wfCctOptsLowPriorityQueueLimit | Wellfleet-CCTOPTS-MIB |