All MIBs › Wellfleet-CCTOPTS-MIB › wfCctOptsFrSetDeNormQ
wfCctOptsFrSetDeNormQ
Module: Wellfleet-CCTOPTS-MIB
OID (symbolic): Wellfleet-CCTOPTS-MIB::wfCctOptsFrSetDeNormQ
OID (numeric): 1.3.6.1.4.1.18.3.5.1.4.1.1.38
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Used on Frame Relay interfaces, allows Set of DE ( Discard Eligible ) bit of packets that end up in PQ's Normal Queue, the Default is Don't Set DE bit
What is wfCctOptsFrSetDeNormQ?
On Frame Relay interfaces, controls whether the DE (Discard Eligible) bit is set on packets in the Priority Queueing normal queue: default(1) does not set it, setdebit(2) sets it. Use setdebit if you want normal traffic to be marked as droppable by the carrier during congestion.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.38 snmpwalk -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsFrSetDeNormQ
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.38.1 snmpget -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsFrSetDeNormQ.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.1.4.1.1.38.1 i <value>
Start monitoring Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-CCTOPTS-MIB::wfCctOptsFrSetDeNormQ OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5 | wfApplication | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1 | wfDataLink | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.1.4 | wfCircuitOptsGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.5.1.4.1 | wfCctOptsTable | Wellfleet-CCTOPTS-MIB |
| 1.3.6.1.4.1.18.3.5.1.4.1.1 | wfCctOptsEntry | Wellfleet-CCTOPTS-MIB |
| 1.3.6.1.4.1.18.3.5.1.4.1.1.38 | wfCctOptsFrSetDeNormQ | Wellfleet-CCTOPTS-MIB |