Wellfleet-CCTOPTS-MIB :: wfCctOptsCngcPortTrfPriority

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-CCTOPTS-MIB › wfCctOptsCngcPortTrfPriority

wfCctOptsCngcPortTrfPriority

Module: Wellfleet-CCTOPTS-MIB

OID (symbolic): Wellfleet-CCTOPTS-MIB::wfCctOptsCngcPortTrfPriority

OID (numeric): 1.3.6.1.4.1.18.3.5.1.4.10.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Defines the traffic priority level of all the incoming packets on this port. CNGC_PRIORITY_TWO - Default value Set all incoming user traffic packets to priority 2. CNGC_PRIORITY_ONE - Set all incoming packets to priority 1. CNGC_PRIORITY_TWO - Set all incoming packets to priority 2. CNGC_PRIORITY_THREE - Set all incoming packets to priority 3. Priority 0 is reserved for network critical packets like OSPF, FR LMI and SMDS heartbeat, Cross Net polling and is not available for user traffic.

What is wfCctOptsCngcPortTrfPriority?

Priority level (one to three, default two) assigned to all incoming user packets on this port. Priority 0 is reserved for network-critical packets like OSPF, Frame Relay LMI, SMDS heartbeat and cross-net polling, so user traffic cannot use it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.10.1.14
snmpwalk -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsCngcPortTrfPriority

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.10.1.14.1
snmpget -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsCngcPortTrfPriority.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.1.4.10.1.14.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> wfCctOptsCngcPortTrfPriority.1

Start monitoring Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-CCTOPTS-MIB::wfCctOptsCngcPortTrfPriority OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5wfApplicationWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.1wfDataLinkWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.1.4wfCircuitOptsGroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.5.1.4.10wfCctOptsCngcTableWellfleet-CCTOPTS-MIB
1.3.6.1.4.1.18.3.5.1.4.10.1wfCctOptsCngcEntryWellfleet-CCTOPTS-MIB
1.3.6.1.4.1.18.3.5.1.4.10.1.14wfCctOptsCngcPortTrfPriorityWellfleet-CCTOPTS-MIB