Wellfleet-CCTOPTS-MIB :: wfCctOptsCngcLinkType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-CCTOPTS-MIB › wfCctOptsCngcLinkType

wfCctOptsCngcLinkType

Module: Wellfleet-CCTOPTS-MIB

OID (symbolic): Wellfleet-CCTOPTS-MIB::wfCctOptsCngcLinkType

OID (numeric): 1.3.6.1.4.1.18.3.5.1.4.10.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Defines whether the circuit is an access link or inter-nodal link (trunk). Traffic monitoring, traffic priority determination, traffic discardability level determination are done at access link and each incoming packet on an access link is tagged with the information. Inter-nodal link (trunk) uses the above tagged information in packets for priority queueing and discarding packets during congestion. WARNING - It is important to set the appropriate link type for this attribute otherwise congestion control will not work. The default value for this attribute is access link. This attribute value must be changed to CNGC_LINK_INTER_NODAL for inter-nodal link(trunk).

What is wfCctOptsCngcLinkType?

Whether the circuit is an access link, access(1), or an inter-nodal link (trunk), nodal(2); default access. Access links tag each incoming packet with priority and discard information that trunks use for queueing and discarding; the source warns that the wrong setting breaks congestion control, so set nodal on trunks.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.10.1.10
snmpwalk -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsCngcLinkType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.1.4.10.1.10.1
snmpget -v2c -c public <target> Wellfleet-CCTOPTS-MIB::wfCctOptsCngcLinkType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.1.4.10.1.10.1 i <value>

Start monitoring Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-CCTOPTS-MIB::wfCctOptsCngcLinkType OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks multiprotocol routers with WAN circuit interfaces (line/encapsulation config status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5wfApplicationWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.1wfDataLinkWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.5.1.4wfCircuitOptsGroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.5.1.4.10wfCctOptsCngcTableWellfleet-CCTOPTS-MIB
1.3.6.1.4.1.18.3.5.1.4.10.1wfCctOptsCngcEntryWellfleet-CCTOPTS-MIB