All MIBs › Wellfleet-ATM-LE-MIB › wflecFlushEnable
wflecFlushEnable
Module: Wellfleet-ATM-LE-MIB
OID (symbolic): Wellfleet-ATM-LE-MIB::wflecFlushEnable
OID (numeric): 1.3.6.1.4.1.18.3.5.9.5.20.1.1.25
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Flush Protocol enable/disable - ATM_LEC_FLUSH_ENABLED - ATM LE flush protocol is used when switching VCs. If the Flush timeout (wflecFlushTimeOut) expires data for that MAC address will start flowing over the old VC again. ATM_LEC_FLUSH_DISABLED - ATM LE flush protocol is not used. Instead data for that MAC address will automatically start flowing over the new VC once the Path Switching delay timeout (wflecPathSwitchingDelay) has expired.
What is wflecFlushEnable?
Toggles whether the ATM LE flush protocol is used when switching between VCs; enabled (default) uses flush handshaking with a fallback if wflecFlushTimeOut expires, disabled instead relies on wflecPathSwitchingDelay to time the cutover.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.5.20.1.1.25 snmpwalk -v2c -c public <target> Wellfleet-ATM-LE-MIB::wflecFlushEnable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.5.20.1.1.25.1 snmpget -v2c -c public <target> Wellfleet-ATM-LE-MIB::wflecFlushEnable.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.9.5.20.1.1.25.1 i <value>
Start monitoring Wellfleet/Bay Networks router with ATM interfaces, legacy (LEC/ELAN join-state status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-ATM-LE-MIB::wflecFlushEnable OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks router with ATM interfaces, legacy (LEC/ELAN join-state status) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5 | wfApplication | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.9 | wfWanGroup | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.9.5 | wfAtmGroup | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.9.5.20 | wfAtmLeGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.5.9.5.20.1 | wfAtmLecConfigTable | Wellfleet-ATM-LE-MIB |
| 1.3.6.1.4.1.18.3.5.9.5.20.1.1 | wfAtmLecConfigEntry | Wellfleet-ATM-LE-MIB |
| 1.3.6.1.4.1.18.3.5.9.5.20.1.1.25 | wflecFlushEnable | Wellfleet-ATM-LE-MIB |