All MIBs › Wellfleet-ASR-MIB › wfAsrHoldDownTimer
wfAsrHoldDownTimer
Module: Wellfleet-ASR-MIB
OID (symbolic): Wellfleet-ASR-MIB::wfAsrHoldDownTimer
OID (numeric): 1.3.6.1.4.1.18.3.5.9.11.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The hold down timer is used to prevent retries to a destination that the SVC setup process has failed on. This value would be used if filter/flow spec information is not returned from NHS.
What is wfAsrHoldDownTimer?
Sets how long, in seconds, ASR waits before retrying a destination whose SVC setup previously failed, used specifically when the Next Hop Server didn't return filter or flow-spec information. It prevents the router from hammering an unreachable destination with repeated setup attempts.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.11.1.7 snmpwalk -v2c -c public <target> Wellfleet-ASR-MIB::wfAsrHoldDownTimer
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.5.9.11.1.7.1 snmpget -v2c -c public <target> Wellfleet-ASR-MIB::wfAsrHoldDownTimer.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.5.9.11.1.7.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> wfAsrHoldDownTimer.1
Start monitoring Wellfleet/Bay Networks/Nortel routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-ASR-MIB::wfAsrHoldDownTimer OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks/Nortel routers from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | CMU-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5 | wfApplication | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.9 | wfWanGroup | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.5.9.11 | wfAsrGroup | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.5.9.11.1 | wfAsrBase | Wellfleet-ASR-MIB |
| 1.3.6.1.4.1.18.3.5.9.11.1.7 | wfAsrHoldDownTimer | Wellfleet-ASR-MIB |